MOTION‑CONNECT 500
|
6
|
F
|
X
|
5
|
0
|
❑
|
2
|
–
|
2
|
❑
|
❑
|
❑
|
❑
|
–
|
.
|
.
|
.
|
.
|
MOTION‑CONNECT 800PLUS
|
6
|
F
|
X
|
8
|
0
|
❑
|
2
|
–
|
2
|
❑
|
❑
|
❑
|
❑
|
–
|
.
|
.
|
.
|
.
|
6FX2 cables
|
6
|
F
|
X
|
2
|
0
|
0
|
2
|
–
|
1
|
D
|
C
|
❑
|
0
|
–
|
.
|
.
|
.
|
.
|
|
↓
|
|
|
|
|
|
|
|
|
|
|
|
|
Pre-assembled at motor and module ends
|
0
|
|
|
|
|
|
|
|
|
|
|
|
|
Pre-assembled at motor end, connector at module end supplied separately 1)
|
1
|
|
|
|
|
|
|
|
|
|
|
|
|
Pre-assembled at module end, connector at motor end supplied separately 1)
|
4
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Variant: Signal cables for integrated encoder
|
|
|
|
|
|
|
|
|
|
|
DRIVE‑CLiQ basic cable between
|
and
|
|
↓
|
↓
|
↓
|
↓
|
|
|
|
|
|
Power Module/Motor Module/SMC with IP20 connector
|
Power Module/Motor Module/SMC with IP20 connector
|
|
D
|
C
|
0
|
0
|
|
|
|
|
|
Power Module/Motor Module/SMC with RJ45/IP20 connector
|
Motor/encoder/SME RJ45/IP67 connector 2)
|
|
D
|
C
|
1
|
0
|
|
|
|
|
|
Power Module/Motor Module/SMC with RJ45/IP20 connector
|
Encoder connector M12
|
|
D
|
C
|
3
|
0
|
|
|
|
|
|
Power Module/Motor Module/SMC with RJ45/IP20 connector
|
Motor connector M17
|
|
D
|
C
|
4
|
0
|
|
|
|
|
|
DME20/cabinet bushing/coupler RJ45
|
Motor/encoder/SME RJ45/IP67 connector
|
|
D
|
C
|
2
|
0
|
|
|
|
|
|
Extension between DRIVE‑CLiQ cable with connector
|
and
|
|
|
|
|
|
|
|
|
|
|
RJ45
|
Motor/encoder/SME RJ45/IP67 connector
|
|
D
|
C
|
2
|
0
|
|
|
|
|
|
M12
|
Encoder connector M12
|
|
D
|
C
|
3
|
4
|
|
|
|
|
|
M17
|
Motor connector M17
|
|
D
|
C
|
4
|
4
|
|
|
|
|
|
DRIVE‑CLiQ adapter cable between
|
and
|
|
|
|
|
|
|
|
|
|
|
M12
|
Motor connector RJ45
|
|
D
|
C
|
3
|
8
|
|
|
|
|
|
M17
|
Motor connector RJ45
|
|
D
|
C
|
4
|
2
|
|
|
|
|
|
RJ45/IP67
|
Motor connector M12
|
|
D
|
C
|
3
|
6
|
|
|
|
|
|
RJ45/IP67
|
Encoder connector M17
|
|
D
|
C
|
4
|
8
|
|
|
|
|
|
M17
|
Encoder connector M12
|
|
D
|
C
|
4
|
6
|
|
|
|
|
|
Basic cable between
|
and motor with
|
|
|
|
|
|
|
|
|
|
|
SMC20
|
Incremental encoder (sin/cos 1 Vpp) full-thread connector, M23
|
|
C
|
A
|
3
|
1
|
|
|
|
|
|
SMC30
|
Incremental encoder (HTL) full-thread connector, M23
|
|
A
|
H
|
0
|
0
|
|
|
|
|
|
CU310‑2/D410‑2
|
Incremental encoder (HTL) full-thread connector, M23
|
|
A
|
H
|
1
|
1
|
|
|
|
|
|
SMC20
|
Absolute encoder full-thread connector, M23
|
|
E
|
Q
|
1
|
0
|
|
|
|
|
|
SMC10
|
Resolver full-thread connector, M23
|
|
C
|
F
|
0
|
2
|
|
|
|
|
|
SMC20
|
Incremental encoder (sin/cos 1 Vpp) SPEED‑CONNECT connector, M23
|
|
C
|
Q
|
3
|
1
|
|
|
|
|
|
SMC20
|
Incremental encoder SPEED‑CONNECT connector, M17
|
|
C
|
N
|
2
|
0
|
|
|
|
|
|
SMC20
|
Absolute encoder SPEED‑CONNECT connector, M23
|
|
E
|
Q
|
3
|
1
|
|
|
|
|
|
SMC20
|
Absolute encoder SPEED‑CONNECT connector, M17
|
|
E
|
N
|
2
|
0
|
|
|
|
|
|
SMC10
|
Resolver SPEED‑CONNECT connector, M17
|
|
F
|
N
|
2
|
0
|
|
|
|
|
|
Extension between basic cable with connector
|
and motor connector
|
|
↓
|
↓
|
↓
|
↓
|
|
|
|
|
|
Full-thread or SPEED‑CONNECT
|
Full-thread or SPEED‑CONNECT
|
|
|
|
|
4
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Variant: Signal cables for external encoder
|
|
|
|
|
|
|
|
|
|
|
Basic cable between
|
and
|
|
↓
|
↓
|
↓
|
↓
|
|
|
|
|
|
SMC30
|
Incremental encoder 6FX2001‑2 (TTL/supply 5 V) full-thread connector
|
|
C
|
R
|
0
|
0
|
|
|
|
|
|
SMC30
|
Incremental encoder 1XP8012-2./1XP8032-2. (TTL/supply 24 V) full-thread connector
|
|
C
|
D
|
2
|
4
|
|
|
|
|
|
SMC20
|
Incremental encoder 6FX2001‑3 (sin/cos 1 Vpp) full-thread connector
|
|
C
|
G
|
0
|
0
|
|
|
|
|
|
SMC30
|
Incremental encoder 6FX2001‑4 (HTL) full-thread connector
|
|
C
|
A
|
1
|
2
|
|
|
|
|
|
SMC30
|
Incremental encoder 1XP8012-1./1XP8032-1. (HTL) full-thread connector
|
|
C
|
A
|
1
|
2
|
|
|
|
|
|
SMC30
|
Absolute encoder with SSI 1XP8014-2./1XP8024-2. (DC 24 V) full-thread connector
|
|
C
|
C
|
0
|
6
|
|
|
|
|
|
SMC30
|
Absolute encoder 6FX2001‑5.S (SSI) full-thread connector
|
|
C
|
C
|
1
|
1
|
|
|
|
|
|
SMC20
|
Absolute encoder 6FX2001‑5.E (EnDat 2.1) full-thread connector
|
|
C
|
H
|
0
|
0
|
|
|
|
|
|
SMC20
|
Absolute encoder 1XP8014-10/1XP8024-10 (EnDat 2.1) full-thread connector
|
|
C
|
H
|
0
|
0
|
|
|
|
|
|
SMC10
|
Resolver 1XP8013-1./1XP8023-1. full-thread connector
|
|
C
|
F
|
0
|
6
|
|
|
|
|
|
Extension between basic cable with connector
|
and motor connector
|
|
↓
|
↓
|
↓
|
↓
|
|
|
|
|
|
Full-thread
|
Full-thread
|
|
|
|
|
4
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Variant: Signal cables for temperature sensor
|
6
|
F
|
X
|
8
|
0
|
0
|
2
|
-
|
2
|
S
|
L
|
❑
|
❑
|
–
|
.
|
.
|
.
|
.
|
Adapter cable with M17 socket on SIMOTICS T‑1FW6 terminals
|
0
|
0
|
|
|
|
|
|
Adapter cable with M17 socket on SIMOTICS L‑1FN3100/L‑1FN3150
|
0
|
1
|
|
|
|
|
|
Adapter cable with M17 socket on SIMOTICS L‑1FN3300 ... L‑1FN3900
|
0
|
2
|
|
|
|
|
|
Extension to basic cable between SME12x and SIMOTICS L‑1FN33)/T‑1FW6
|
1
|
0
|
|
|
|
|
|
Basic cable between TM120 and SIMOTICS L‑1FN33)/SIMOTICS T‑1FW6
|
2
|
0
|
|
|
|
|
|
|
|
|
|
|
Length code
|
|
|
|
|