Overview
ENG_150678.XML
P_NC01_XX_01823
MOTION-CONNECT DRIVE‑CLiQ signal cable with IP20/IP67 connector
Signal cables are pre-assembled and are sold by the meter for the connection of a variety of components.
The following different types of cable are available:
- DRIVE‑CLiQ signal cables
- MOTION-CONNECT DRIVE-CLiQ signal cables
- MOTION‑CONNECT pre-assembled signal cables
Type of delivery for pre-assembled signal cables
Usage
|
Connection Module end/ motor end
|
24 V cores
|
6FX2...
|
MOTION‑CONNECT 500 6FX5...
|
MOTION‑CONNECT 800PLUS 6FX8...
|
Length stages
|
DRIVE-CLiQ signal cable
|
Components with DRIVE-CLiQ interface, with internal or external 24 V DC power supply in the control cabinet
|
RJ45 IP20/RJ45 IP20
|
without
|
≤ 70 m (230 ft)
|
–
|
–
|
to the decimeter
|
Components with DRIVE-CLiQ interface in the control cabinet
|
RJ45 IP20/RJ45 IP20
|
with
|
–
|
≤ 100 m (328 ft)
|
≤ 75 m (246 ft)
|
to the decimeter
|
For built-in or built-on encoder systems with DRIVE-CLiQ interface.
|
RJ45 IP20/RJ45 IP67
|
with
|
RJ45 IP67/RJ45 IP67
|
Basic cable
|
RJ45 IP20/M17
|
with
|
Extension
|
M17/M17
|
Adapter cable
|
RJ45 IP67/M17
|
M17/RJ45 IP67
|
Basic cable
|
RJ45 IP20/M12
|
with
|
–
|
≤ 100 m (328 ft)
|
≤ 75 m (246 ft)
|
To the meter up to 20 m (65.6 ft), beyond that in steps of 5 m (16.4 ft)
|
Extension
|
M12/M12
|
≤ 30 m (98.4 ft)
|
≤ 30 m (98.4 ft)
|
Adapter cable
|
RJ45 IP67/M12
|
≤ 100 m (328 ft)
|
≤ 75 m (246 ft)
|
M12/RJ45 IP67
|
≤ 30 m (98.4 ft)
|
≤ 30 m (98.4 ft)
|
M17/M12
|
≤ 100 m (328 ft)
|
≤ 75 m (246 ft)
|
Above 30 kg (66.2 lb) or 100 m (328 ft), the cables are supplied on drums, otherwise as coils.
Application
ENG_452002.XML
DRIVE‑CLiQ signal cables
DRIVE-CLiQ signal cables are used to connect components with DRIVE-CLiQ connections which have a separate or external 24 V DC power supply.
MOTION‑CONNECT DRIVE‑CLiQ signal cables
MOTION‑CONNECT DRIVE‑CLiQ signal cables with 24 V DC cores are used whenever components with DRIVE-CLiQ connections must meet high requirements such as mechanical stress and oil resistance, e.g. where a connection is made outside the cabinet between:
- Motor Modules and Sensor Modules
- Motor Modules and motors with DRIVE-CLiQ interface
- Motor Modules and direct measuring systems with third-party-DRIVE-CLiQ interface
MOTION‑CONNECT DRIVE‑CLiQ signal cables have 24 V DC cores .
MOTION-CONNECT pre-assembled signal cables
MOTION-CONNECT pre-assembled signal cables are used whenever motor encoders on motors without DRIVE-CLiQ interface are connected to Sensor Modules.
Design
ENG_452001.XML
If pre-assembled signal cables are to be installed in a cable carrier in such a way that the connector would inhibit assembly, pre-assembled cables without assembled connector can also be supplied. In this case, the contacts of the cables are crimped and the connector enclosure is supplied separately. After installing the cables, the customer assembles the connector enclosure.
The 6FX.002-2....-.... signal cables are available with crimped contacts and with the connector enclosure supplied separately (not in the case of DRIVE-CLiQ signal cables or signal cables with bare wire ends).
Signal cables with separately supplied module-end connector enclosure. In this case, the 6th position of the Article No. must be changed from 0 to 1:
6FX.012-2C...-.... (not for signal cables for connection via terminals or 6FX.002-2AH00-...., 6FX.002-2CA12-....).
Signal cables with separately supplied motor-end connector enclosure. In this case, the 6th position of the Article No. must be changed from 0 to 4:
6FX.042-2C...-.... (not for signal cables for connection via terminals or 6FX8002-2BA20-...., 6FX8002-2BA21-....).
Note:
Once the contacts have latched into the insulator, they can no longer be removed.
Technical specifications
ENG_150677.XML
DRIVE‑CLiQ signal cables
|
DRIVE‑CLiQ
|
DRIVE‑CLiQ MOTION‑CONNECT 500
|
DRIVE‑CLiQ MOTION‑CONNECT 800PLUS
|
|
6FX2...‑1DC..‑....
|
6FX5...‑.DC..‑....
|
6FX8...‑.DC..‑....
|
Certificate of suitability
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
UL STYLE 2502/CSA-N.210.2-M90
|
UL STYLE 2502/CSA-N.210.2-M90
|
UL STYLE 20236/CSA-N.210.2-M90
|
|
Yes
|
Yes
|
Yes
|
Rated voltage according to EN 50395
|
30 V
|
30 V
|
30 V
|
Test voltage, rms
|
500 V
|
500 V
|
500 V
|
Operating temperature on the surface
|
|
|
|
|
‑20 … +80 °C (‑4 ... +176 °F)
|
‑20 … +80 °C (‑4 ... +176 °F)
|
‑20 … +80 °C (‑58 ... +176 °F)
|
|
–
|
0 … 60 °C (+32 ... +140 °F)
|
‑20 … +60 °C (‑4 ... +140 °F)
|
Tensile stress, max.
|
|
|
|
|
45 N/mm2 (6526 lbf/in2)
|
80 N/mm2 (11603 lbf/in2)
|
50 N/mm2 (7252 lbf/in2)
|
|
–
|
30 N/mm2 (4351 lbf/in2)
|
20 N/mm2 (2901 lbf/in2)
|
Smallest bending radius
|
|
|
|
|
50 mm (1.97 in)
|
35 mm (1.38 in)
|
35 mm (1.38 in)
|
|
–
|
125 mm (4.92 in)
|
75 mm (2.95 in)
|
Torsional stress
|
–
|
Absolute 30°/m
|
Absolute 30°/m
|
Bending
|
–
|
100000
|
10 million
|
Traversing velocity
|
–
|
30 m/min (98.4 ft/min)
|
300 m/min (984 ft/min)
|
Acceleration
|
–
|
2 m/s2 (6.56 ft/s2)
|
Up to 50 m/s2 (164 ft/s2) see charasteristic curves
|
Insulation material, incl. jacket
|
CFC/silicone-free
|
CFC/silicone-free
|
CFC/halogen/silicone-free IEC 60754‑1/DIN VDE 0472‑815
|
Oil resistance
|
EN 60811-404:2012
|
EN 60811-404:2012 (mineral oil only)
|
EN 60811-404:2012
|
Outer jacket
|
PVC
|
PVC
|
PUR, HD22.10 S2 (VDE 0282, Part 10)
|
|
Gray RAL 7032
|
DESINA color green RAL 6018
|
DESINA color green RAL 6018
|
Flame-retardant
|
EN 60332‑1‑1 to 1‑3
|
EN 60332‑1‑1 to 1‑3
|
EN 60332‑1‑1 to 1‑3
|
1) The File No. is printed on the cable jacket.
Degree of protection of pre-assembled signal cables and their extensions when closed and connected: IP67.
Signal cables
|
MOTION‑CONNECT 500
|
MOTION‑CONNECT 800PLUS
|
|
6FX50..‑....‑....
|
6FX80..‑.....‑....
|
Certificate of suitability
|
|
|
|
Yes
|
Yes
|
|
UL758-CSA-C22.2-N.210.2-M90
|
UL758-CSA-C22.2-N.210.2-M90
|
|
Yes
|
Yes
|
Rated voltage according to EN 50395
|
30 V
|
30 V
|
Test voltage, rms
|
500 V
|
500 V
|
Operating temperature on the surface
|
|
|
|
-20 … +80 °C (‑4 ... +176 °F)
|
-50 … +80 °C (‑58 ... +176 °F)
|
|
0 … 60 °C (+32 ... +140 °F)
|
-20 … +60 °C (‑4 ... +140 °F)
|
Tensile stress, max.
|
|
|
|
50 N/mm2 (7252 lbf/in2)
|
50 N/mm2 (7252 lbf/in2)
|
|
20 N/mm2 (2901 lbf/in2)
|
20 N/mm2 (2901 lbf/in2)
|
Smallest bending radius
|
|
|
|
60 mm (2.36 in)
|
4 x Dmax
|
|
100 mm (3.94 in)
|
70 mm (2.76 in)2)
|
Torsional stress
|
Absolute 30°/m
|
Absolute 30°/m
|
Bending
|
2 million
|
10 million
|
Traversing velocity
|
180 m/min (591 ft/min)
|
Up to 300 m/min (984 ft/min)
|
Acceleration
|
5 m/s2 (16.41 ft/s2)
|
Up to 50 m/s2 (164 ft/s2) see charasteristic curves
|
Insulation material, incl. jacket
|
CFC/silicone-free
|
CFC/halogen/silicone-free IEC 60754‑1/DIN VDE 0472‑815
|
Oil resistance
|
EN 60811-404:2012 (mineral oil only)
|
EN 60811-404:2012
|
Outer jacket
|
PVC
|
PUR, HD22.10 S2 (VDE 0282, Part 10)
|
|
DESINA color green RAL 6018
|
DESINA color green RAL 6018
|
Flame-retardant
|
EN 60332‑1‑1 to 1‑3
|
EN 60332‑1‑1 to 1‑3
|
1) The File No. is printed on the cable jacket.
2) Exception: 6FX8002-2SL..-....; smallest bending radius (flexible): 85 mm (3.35 in).
Degree of protection of pre-assembled signal cables and their extensions when closed and connected: IP67.