suitability for use
|
Cable for permanent installation indoors and outdoors, UL approval
|
Cable for applications with high mechanical loading, and motion (e.g. trailing cables), no UL approval
|
Cable for applications with high mechanical loading and motion (e.g. trailing cables), UL approval
|
version of the assembled FO cable
|
sold by the meter
|
sold by the meter
|
sold by the meter
|
cable designation
|
AT-V(ZN)YY 2K 200/230
|
AT-V(ZN)Y(ZN)11Y 2K 200/230
|
AT-V(ZN)Y(ZN)Y 2K 200/230
|
optical data
|
|
|
|
attenuation factor per length
|
|
|
|
|
10 dB/km
|
10 dB/km
|
10 dB/km
|
|
10 dB/km
|
10 dB/km
|
10 dB/km
|
bandwidth length product
|
|
|
|
|
17 GHz·m
|
17 GHz·m
|
17 GHz·m
|
mechanical data
|
|
|
|
number of fibers per FOC core
|
1
|
1
|
1
|
number of FO cores per FOC cable
|
2
|
2
|
2
|
version of the FO conductor fiber
|
Step index fiber 200/230 µm
|
Step index fiber 200/230 µm
|
Step index fiber 200/230 µm
|
outer diameter
|
|
|
|
|
200 µm
|
200 µm
|
200 µm
|
|
230 µm
|
230 µm
|
230 µm
|
|
2.2 mm
|
2.2 mm
|
2.2 mm
|
symmetrical deviation of the outer diameter of the FOC core sheath
|
0.1 mm
|
0.1 mm
|
0.1 mm
|
outer diameter of the cable
|
7.2 mm
|
8.8 mm
|
8.8 mm
|
symmetrical deviation of the outer diameter of the line
|
0.5 mm
|
0.5 mm
|
0.5 mm
|
material
|
|
|
|
|
Quartz glass
|
Quartz glass
|
Quartz glass
|
|
Special polymer
|
Special polymer
|
Special polymer
|
|
PVC
|
PVC
|
PVC
|
|
PVC
|
PUR
|
PVC
|
|
Aramid fibers
|
Aramid fibers
|
Aramid fibers
|
color
|
|
|
|
|
orange/black
|
orange/black
|
orange/black
|
|
green
|
green
|
green
|
bending radius
|
|
|
|
|
70 mm
|
130 mm
|
130 mm
|
|
105 mm
|
175 mm
|
175 mm
|
number of bending cycles
|
|
5 000 000
|
5 000 000
|
tensile load
|
|
|
|
|
800 N
|
2 000 N
|
2 000 N
|
|
100 N
|
800 N
|
800 N
|
short-term shear force per length
|
500 N/cm
|
500 N/cm
|
500 N/cm
|
continuous shear force per length
|
300 N/cm
|
300 N/cm
|
300 N/cm
|
weight per length
|
45 kg/km
|
85 kg/km
|
85 kg/km
|
ambient conditions
|
|
|
|
ambient temperature
|
|
|
|
|
-40 ... +90 °C
|
-25 ... +75 °C
|
-25 ... +75 °C
|
|
-40 ... +90 °C
|
-30 ... +75 °C
|
-30 ... +75 °C
|
|
-40 ... +90 °C
|
-30 ... +75 °C
|
-30 ... +75 °C
|
|
-5 ... +50 °C
|
-5 ... +50 °C
|
-5 ... +50 °C
|
fire behavior
|
flame-resistant acc. to IEC 60332-1-2 and IEC 60332-3-22 (Cat. A)
|
flame-retardant
|
flame-resistant acc. to IEC 60332-1-2 and IEC 60332-3-22 (Cat. A)
|
class of burning behaviour according to EN 13501-6
|
Eca
|
Fca
|
Eca
|
chemical resistance
|
|
|
|
|
acc. to IEC 60811-404 with test oil IRM 902 (acc. to ISO 1817), +70 °C, 4 h
|
resistant
|
acc. to IEC 60811-404 with test oil IRM 902 (acc. to ISO 1817), +70 °C, 4 h
|
|
conditional resistance
|
resistant
|
conditional resistance
|
|
conditional resistance
|
conditional resistance
|
conditional resistance
|
radiological resistance to UV radiation
|
resistant
|
resistant
|
resistant
|
product features, product functions, product components general
|
|
|
|
product feature
|
|
|
|
|
No
|
No
|
No
|
|
Yes
|
Yes
|
Yes
|
product component rodent protection
|
No
|
No
|
No
|
wire length
|
|
|
|
|
100 m
|
100 m
|
100 m
|
|
400 m
|
400 m
|
400 m
|
standards, specifications, approvals
|
|
|
|
certificate of suitability
|
|
|
|
|
Yes; c(UL)us OFN FT4
|
|
Yes; c(UL)us OFN FT4
|
|
Yes
|
Yes
|
Yes
|
reference code
|
|
|
|
|
WH
|
WH
|
WH
|
|
WHA
|
WHA
|
WHA
|
further information internet links
|
|
|
|
internet link
|
|
|
|
|
https://support.industry.siemens.com/cs/ww/en/view/109766358
|
https://support.industry.siemens.com/cs/ww/en/view/109766358
|
https://support.industry.siemens.com/cs/ww/en/view/109766358
|
|
https://www.siemens.com/tstcloud
|
https://www.siemens.com/tstcloud
|
https://www.siemens.com/tstcloud
|
|
https://www.siemens.com/simatic-net
|
https://www.siemens.com/simatic-net
|
https://www.siemens.com/simatic-net
|
|
https://sieportal.siemens.com/
|
https://sieportal.siemens.com/
|
https://sieportal.siemens.com/
|
|
https://www.automation.siemens.com/bilddb
|
https://www.automation.siemens.com/bilddb
|
https://www.automation.siemens.com/bilddb
|
|
https://www.siemens.com/cax
|
https://www.siemens.com/cax
|
https://www.siemens.com/cax
|
|
https://support.industry.siemens.com
|
https://support.industry.siemens.com
|
https://support.industry.siemens.com
|
security information header
|
|
|
|
security information
|
Siemens provides products and solutions with industrial cybersecurity functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial cybersecurity concept. Siemens’ products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks. Such systems, machines and components should only be connected to an enterprise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures (e.g. firewalls and/or network segmentation) are in place. For additional information on industrial cybersecurity measures that may be implemented, please visit www.siemens.com/cybersecurity-industry. Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Cybersecurity RSS Feed under https://www.siemens.com/cert. (V4.7)
|
Siemens provides products and solutions with industrial cybersecurity functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial cybersecurity concept. Siemens’ products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks. Such systems, machines and components should only be connected to an enterprise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures (e.g. firewalls and/or network segmentation) are in place. For additional information on industrial cybersecurity measures that may be implemented, please visit www.siemens.com/cybersecurity-industry. Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Cybersecurity RSS Feed under https://www.siemens.com/cert. (V4.7)
|
Siemens provides products and solutions with industrial cybersecurity functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial cybersecurity concept. Siemens’ products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks. Such systems, machines and components should only be connected to an enterprise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures (e.g. firewalls and/or network segmentation) are in place. For additional information on industrial cybersecurity measures that may be implemented, please visit www.siemens.com/cybersecurity-industry. Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Cybersecurity RSS Feed under https://www.siemens.com/cert. (V4.7)
|