Overview
ENG_694090.XML
P_ST70_XX_08724
SIMATIC ET 200eco PN video
- Compact block I/O for processing digital, fail-safe digital, analog and IO-Link signals for connecting to bus systems with Ethernet-based protocols PROFINET, EtherNet/IP and Modbus TCP
- Cabinet-free installation in degree of protection IP65/67/69K with M12 connection system
- Extremely rugged and resistant metal enclosure
- Housing type of the I/O devices with 2x M12 L-coded power connectors
- 45 mm x 200 mm x 48 mm (W x H x D) with 8 x M12 for digital signals and IO-Link
- Housing type of the I/O devices with 2x M12 A-coded power connectors
- 30 mm x 200 mm x 37 mm (W x H x D) with 4 x M12 for digital signals and IO-Link
- 60 mm x 175 mm x 37 mm (W x H x D) with 8 x M12 for digital and fail-safe digital signals as well as IO-Link
- 60 mm x 175 mm x 37 mm (W x H x D) with 4 x M12 or 8 x M12 for analog signals
- Fieldbus connection: 2 x M12 D-coded and automatic PROFINET addressing
- Data transfer rate 100 Mbps
- LLDP neighborhood discovery for topological configuration
- Fast startup (run-up within approx. 0.5 seconds)
- Channel-specific diagnostics, identification and maintenance data IM0 ... IM3
- Firmware update
- Ambient temperature range -40 °C to 60 °C
- Can be used in hazardous areas in zones 2 and 22
- Can be used outdoors
- Increase in communication availability due to Media Redundancy Protocol (MRP) on PROFINET as well as operation on S7-1500 R/H or S7-400H by means of S2 redundancy
- Variants of the I/O devices with M12 L-coded power connectors:
- DI 8
- DI 16
- DQ 8 (0.5 A)
- DQ 8 (2 A)
- DIQ 16 (0.5A/2A)
- 8 IO-Link + DI 4
- 8 IO-Link + DIQ 8
- 4 IO-Link + DIQ 12
- AI 8 (TC, RTD)
- AIQ 8 (U, I)
- TM PosInput 2
- Variants of the I/O devices with M12 A-coded power connectors:
- 8 DI
- 16 DI
- 8 DQ (2 A)
- 8 DQ (1.3 A)
- 8 DQ (0.5 A)
- 16 DQ (1.3 A)
- 8 DI/DQ (1.3 A)
- 8 F-DI/3 F-DO (2 A)
- 8 AI (U, I, TC, RTD)
- 8 AI (TC, RTD)
- 4 AO (U, I)
- 4 IO-Link
- 4 IO-Link + 8 DI + 4 DQ (1.3 A)
Benefits
ENG_694091.XML
Simple use:
- Simple and flexible installation and wiring thanks to intelligent product design
- Shorter commissioning times and plant downtimes thanks to channel-specific diagnostics
Compact design:
- Small dimensions of I/O devices
Strong performance
- Communication connection of sensors and actuators via IO-Link
- High current carrying capacity of the devices with M12 L-coded power connectors
Application
ENG_694092.XML
The compact ET 200eco PN block I/O is a distributed I/O device in degree of protection IP65/67/69K with easy handling and installation.
ET 200eco PN can be used to process digital, fail-safe digital, analog and IO-Link signals as well as counting and position signals on PROFINET. I/O devices with M12-L coded power connectors designed for use on a wide range of Ethernet controllers due to support of the PROFINET, EtherNet/IP and Modbus TCP protocols.
With a high degree of protection, ruggedness and small dimensions, ET 200eco PN is especially well suited for use at machine level.
ET 200eco PN is the seamless supplement for applications with a high degree of protection in addition to the modular ET 200pro and ET200AL I/O families.
Design
ENG_694093.XML
ET 200eco PN is a compact module with M12 connections.
For the use and integration of PROFINET applications, a matched module spectrum of I/Os is available:
I/O devices with M12 L-coded power connectors
Number of channels
|
Connection type
|
DI 8
|
8 channels via 8 x M12 glands and single or dual assignment for 8 digital input signals
|
DI 16
|
16 channels via 8 x M12 glands with dual assignment for 16 digital input signals
|
DQ 8
|
8 channels via 8 x M12 glands with single and dual assignment for 8 digital output signals (0.5 A)
|
DQ 8
|
8 channels via 8 x M12 glands with single and dual assignment for 8 digital output signals (2 A)
|
DIQ 16
|
16 channels via 8 x M12 glands with dual assignment for 16 digital input or output signals (0.5 A / 2 A)
|
AI 8
|
8 RTD/TC via 8 x M12 glands
|
AIQ 8
|
6 analog input signals U, I and 2 analog input or analog output signals U, I via 8 x M12 screw connections
|
IO-Link master 8 IO-Link + DI 4
|
8 IO-Link and 4 digital input signals via 8 x M12 glands; IO-Link V1.1; 4 x Class A port and 4 x Class B port
|
8 IO-Link + DIQ 8
|
8 IO-Link and 8 digital input/output signals via 8 x M12 glands; IO-Link V1.1; 8 x Class A port
|
4 IO-Link + DIQ 12
|
4 IO-Link and 12 digital input/output signals via 8 x M12 glands; IO-Link V1.1; 4 x Class A port
|
TM PosInput 2
|
2 channels, each for 24 V incremental, RS-422 incremental or RS-422 SSI signals, 24 V pulse and directional signals. 2 DI, 2 DQ per channel 8-pin M12 for RS-422 signals 5-pin M12 for 24 V signals
|
I/O devices with M12 A-coded power connectors
Number of channels
|
Connection type
|
8 DI
|
8 channels via 4 x M12 glands and dual assignment for 8 digital input signals
|
8 DI
|
8 single channels via 8 x M12 glands for 8 digital input signals
|
16 DI
|
16 channels via 8 x M12 glands with dual assignment for 16 digital input signals
|
8 DQ
|
8 channels via 4 x M12 glands with dual assignment for 8 digital output signals (0.5 A)
|
8 DQ
|
8 channels via 4 x M12 glands with dual assignment for 8 digital output signals (1.3 A)
|
8 DQ
|
8 single channels via 8 x M12 glands for 8 digital output signals (1.3 A)
|
8 DQ
|
8 single channels via 8 x M12 glands for 8 digital output signals (2 A)
|
16 DQ
|
16 channels via 8 x M12 glands with dual assignment for 16 digital output signals (1.3 A)
|
8 DIQ
|
8 channels via 8 x M12 glands for 8 digital input or output signals (1.3 A)
|
8 F-DI/3 F-DQ
|
8 channels for 8 fail-safe digital input signals and 3 channels for 3 fail-safe digital output signals (2 A) via M12 glands
|
8 AI
|
4 U/I + 4 RTD/TC via 8 x M12 glands
|
8 AI
|
8 RTD/TC via 8 x M12 glands
|
4 AO
|
4 U/I via 4 x M12 glands
|
IO-Link master 4 IO-L
|
4 IO-Link, 4 x M12; IO-Link V1.1; Class B port
|
IO-Link master 4 IO-L + 8 DI + 4 DQ
|
4 IO-Link, 8 digital input signals and 4 digital output signals (1.3 A) via 8 x M12 glands with dual assignment; IO-Link V1.0; Class A port
|
Installation
ET 200eco PN I/O devices can be easily installed in every position, i.e. vertical or horizontal installation is possible. They are screwed from the front or side into a machine or assembly line directly on site, where they use M12 connections to connect sensors and actuators. Installation can take place on a level surface, the mounting rail or on aluminum support profiles using sliding blocks.
Power supply
Two power supply units are available which can be used on the one hand by the I/O device and also looped through to an additional I/O device (line topology). The I/O devices with M12 L-coded power connectors can be supplied or forwarded 2x 12 A and the I/O devices with M12 A-coded power connectors 2x 4 A.
In the I/O devices with M12 A-coded power connectors, the power supply units can alternatively be supplied and forwarded via an additional terminal block with up to 10 A.
G_ST70_XX_00623
Power supply with terminal block 10 A
Additionally, the fed power supply units can be distributed over 4 lines by means of a voltage distributor. The distributed power supply units are electronically protected against short-circuits.
G_ST70_XX_00624
Power supply with voltage distributor
Fieldbus connection
The Ethernet-based fieldbus is connected to the ET 200eco PN via an M12 connection and can be looped through to an additional device.
Function
ENG_694094.XML
Mode of operation
The communication of the I/O devices with M12-A coded power connector occurs completely via PROFINET. The communication of the I/O devices with M12 L-coded power connectors occurs via the Ethernet-based protocols PROFINET, EtherNet/IP and Modbus TCP.
Comprehensive diagnostic functions are available for checking the mode of operation of the ET 200eco PN.
The diagnostic information data is indicated by LEDs on the module and can be evaluated by software on the PG/PC or by the PLC.
Comprehensive, channel-specific diagnostics with plain text messages enables location and elimination of system faults in the shortest possible time. Inconvenient plant downtimes belong to the past, and availability is significantly increased.
Configuration
The ET 200eco PN is configured and assigned parameters via TIA Portal, STEP 7 or the configuration tool of the controller used. The MFCT tool (MultiFieldbus Configuration Tool) must be used for configuration in EtherNet/IP and Modbus TCP.
A GSD file is available for connecting the I/O devices which are not configured with TIA Portal to the PROFINET controller. This can be loaded into the configuration tool of the PROFINET controller and provides all relevant information in plain text for the parameterization of the ET 200eco PN.
Configuration of IO-Link is supported by the S7-PCT (Port Configuration Tool).
More information
ENG_694095.XML
General information
is available under this link.
The TIA Selection Tool
is available under this link.