SIMATIC S7-1500F integrated
|
|
|
|
✓
|
PLC user memory:
Program memory in MB / Data memory in MB
|
|
|
|
✓
1.5 / 5
|
Standard motion control functionality
Motion control resources:
|
|
|
|
✓
2400
|
Typ. PLC cycle time1)
|
|
1)
Preconditions:
The specification of a typ. PLC cycle time is highly dependent on the size and configuration of the PLC program. All specifications concerning time values currently have the status "In planning/development" and have to be verified.
|
|
15 ... 20 ms
|
Fieldbus communication via PROFINET IO RT/IRT (X150):
- Number of interfaces / Number of ports
|
|
|
|
✓
1 / 2
|
Distributed I/O via PROFINET (RT/IRT):
|
|
See SiePortal
|
|
|
- Minimum update time for RT
|
|
Min. update time is determined by the time slice set for PROFINET IO communication, by the number of IO devices used, and by the amount of configured user data.
|
|
125 μs 250 μs
|
- Distributed PROFINET devices, maximum number
|
|
|
|
512
|
- Of which IO devices with IRT, max.
|
|
|
|
64
|
Plant communication via PROFINET IO RT (X160):
- Number of interfaces / Number of ports
|
|
|
|
✓
1 / 1
|
Distributed I/O via PROFINET (RT):
|
|
See SiePortal
|
|
|
- Update time for RT (for send cycle of 1 ms)
|
|
Min. update time is determined by the time slice set for PROFINET IO communication, by the number of IO devices used, and by the amount of configured user data.
|
|
1 ... 512 ms
|
- Distributed PROFINET devices for RT, max. number
|
|
|
|
128
|
PROFINET IO controller
|
|
|
|
✓
|
PROFINET IO device
|
|
|
|
✓
|
I/O address area:
|
|
|
|
|
- Inputs – all inputs are in the process image
|
|
16 KB via integrated PROFINET IO interface X150, 8 KB via integrated PROFINET IO interface X160 and 8 KB via integrated PROFIBUS DP interface.
|
|
32 KB
|
- Outputs – all outputs are in the process image
|
|
16 KB via integrated PROFINET IO interface X150, 8 KB via integrated PROFINET IO interface X160 and 8 KB via integrated PROFIBUS DP interface.
|
|
32 KB
|
Bit memory
|
|
|
|
16 KB
|
S7 timers
|
|
|
|
2048
|
IEC timers
|
|
|
|
Any
|
S7 counters
|
|
|
|
2048
|
IEC counters
|
|
|
|
Any
|
Retentive data area
|
|
|
|
768 bytes
|
Usable retentive memory for bit memories, timers, counters, DBs and technological data (axes)
|
|
|
|
700 bytes
|
FB:
|
|
Usable numbers 30 ... 999 and 1024 ... 24999
|
|
|
|
|
|
|
65535
|
|
|
|
|
1 MB
|
FC:
|
|
Usable numbers 30 ... 999 and 1024 ... 24999
|
|
|
|
|
|
|
65535
|
|
|
|
|
1 MB
|
DB:
|
|
Usable numbers 62 ... 70 and 1100 ... 24999
|
|
|
|
|
|
|
59999
|
- Max. size
(optimized/non-optimized block access)
|
|
|
|
16 MB/64 KB
|
Know-how protection:
|
|
|
|
|
|
|
|
|
✓
|
|
|
|
|
✓
|
|
|
|
|
✓
|
|
|
|
|
✓
|
- "Write protection" protection level
|
|
|
|
✓
|
- "Read/write protection" protection level
|
|
|
|
✓
|
- "Complete protection" protection level
|
|
|
|
✓
|
SINUMERIK PP 72/48D PN I/O module
|
|
Quantity limited by I/O quantity structure of PLC
|
6FC5311-0AA00-0AA0
|
O
|
SINUMERIK PP 72/48D 2/2A PN I/O module
|
|
Quantity limited by I/O quantity structure of PLC
|
6FC5311-1AA00-0AA0
|
O
|
PLC programming language STEP 7 Professional:
|
|
With TIA Portal from V15.1
|
|
O
|
|
|
|
|
O
|
- Function block diagram (FBD)
|
|
|
|
O
|
|
|
|
|
O
|
- Structured Control Language (SCL)
|
|
|
|
O
|
- GRAPH for sequential processes
|
|
|
|
O
|
Company network interface (X130), RJ45
Number of interfaces / Number of ports:
|
|
|
|
✓
1 / 1
|
|
|
|
|
1000 Mbps
|
Service network interface (X127), RJ45
Number of interfaces / Number of ports:
|
|
|
|
✓
1 / 1
|
|
|
|
|
1000 Mbps
|