Diagnostics
|
1
|
Factory data
|
X
|
X
|
X
|
X
|
2
|
Diagnostic values
|
X
|
X
|
—
|
X
|
3
|
Logbook
|
X
|
X
|
—
|
X
|
4
|
Display measuring ranges
|
X
|
X
|
—
|
X
|
Calibration
|
20
|
Zero calibration
|
X
|
X
|
—
|
X
|
21
|
Sensitivity calibration
|
X
|
X
|
—
|
X
|
22
|
Zero point/sensitivity setpoints
|
X
|
X
|
—
|
X
|
23
|
Total/individual calibration
|
X
|
X
|
—
|
X
|
24
|
AUTOCAL
|
X
|
X
|
X
|
X
|
25
|
Drift values
|
X
|
X
|
—
|
—
|
26
|
Calibration with air (OXYMAT 64 only)
|
X
|
—
|
—
|
—
|
Measuring ranges (code 1)
|
40
|
Select measuring ranges
|
X
|
X
|
—
|
X
|
41
|
Define measuring ranges
|
X
|
X
|
—
|
X
|
Parameter (code 1)
|
50
|
Electrical time constants
|
X
|
X
|
—
|
X
|
51
|
Limits
|
X
|
X
|
—
|
—
|
52
|
On/off functions
|
X
|
—
|
—
|
X
|
53
|
Status messages
|
X
|
X
|
—
|
—
|
54
|
Graphical measured value representation
|
X
|
X
|
—
|
—
|
55
|
Measured value display
|
X
|
X
|
—
|
—
|
56
|
LCD contrast
|
X
|
—
|
—
|
—
|
57
|
Chopper frequency (ULTRAMAT 6 only) / Magnetic field frequency (OXYMAT 6 only) / Flame ignition (FIDAMAT 6 only)
|
X
|
X
|
—
|
X
|
58
|
Date/time of day
|
X
|
X
|
—
|
X
|
59
|
Measuring point switchover
|
X
|
X
|
—
|
—
|
60
|
Logbook settings
|
X
|
—
|
—
|
X
|
61
|
Vibration compensation (OXYMAT 6 only)
Switch internal valves (FIDAMAT 6 only)
|
X
|
X
|
—
|
X
|
62
|
Set external pressure (FIDAMAT 6 "without pump" only)
|
X
|
X
|
—
|
X
|
Configuration (code 2)
|
70
|
Analog output
|
X
|
X
|
—
|
—
|
71
|
Relay assignment
|
X
|
X
|
—
|
X
|
72
|
Digital inputs
|
X
|
X
|
—
|
X
|
73
|
ELAN configuration
|
X
|
X
|
—
|
—
|
74
|
Reset
|
X
|
X
|
—
|
X
|
75
|
Save/load data
|
X
|
X
|
—
|
X
|
76
|
Suppression of short noise signals
|
X
|
X
|
—
|
X
|
77
|
Measured value memory (analog output)
|
X
|
X
|
—
|
—
|
78
|
Calibration tolerances
|
X
|
X
|
—
|
X
|
79
|
Change codes
|
X
|
X
|
—
|
—
|
80
|
Device test
|
X
|
X
|
—
|
—
|
81
|
Language selection
|
X
|
X
|
—
|
—
|
82
|
Pressure correction (ULTRAMAT 6, OXYMAT 6, OXYMAT 64 and CALOMAT 62 only)
|
X
|
X
|
—
|
—
|
83
|
Correction of cross-interference
|
X
|
X
|
—
|
—
|
84
|
Phase calibration (ULTRAMAT 6 and OXYMAT 6 only)
|
X
|
—
|
—
|
—
|
85
|
Switch valves
|
X
|
—
|
—
|
—
|
86
|
Linear temperature compensation
|
X
|
X
|
—
|
—
|
87
|
Error on/off
|
X
|
—
|
—
|
—
|
89
|
Sample chamber heating (ULTRAMAT 6, OXYMAT 6 and CALOMAT 62 only)
|
X
|
X
|
—
|
—
|
90
|
PROFIBUS configuration
|
X
|
X
|
X
|
X
|
91
|
Startup state (FIDAMAT 6 only)
|
X
|
X
|
—
|
—
|
92
|
Pressure values (FIDAMAT 6 only)
|
X
|
X
|
—
|
—
|
93
|
Units (FIDAMAT 6 only)
|
X
|
—
|
—
|
—
|
Other
|
—
|
Control of external valves
|
—
|
—
|
—
|
X
|
—
|
Software download
|
—
|
X
|
—
|
—
|