1 x PN IO IRT (BusAdapter not included in scope of supply)
PROFIBUS DP
Yes (via CM DP)
Web server
Yes
GB-Ethernet
Yes, 1 x via GB-Ethernet RJ45 interface
Application
ENG_451293.XML
Various graduated performance CPUs are available for the ET 200SP:
Standard CPUs
CPU 1510SP-1 PN: The CPU for smaller applications with moderate requirements regarding program scope and processing speed in discrete production technology. The CPU 1510SP-1 PN can be used as a PROFINET IO controller or as distributed intelligence (PROFINET I-Device).
CPU 1512SP-1 PN: The CPU for applications with moderate requirements regarding program scope and processing speed in discrete production technology. The CPU 1512SP-1 PN can be used as a PROFINET IO controller or as distributed intelligence (PROFINET I-Device).
CPU 1514 SP-2 PN: The CPU for applications with moderate/high requirements regarding program scope, networking and processing speed in discrete production technology. The additional integrated PROFINET interface with separate IP address can be used for network separation, for connecting further PROFINET IO RT devices, or for high-speed communication as an I-Device, for example.
Fail-safe CPUs
CPU 1510SP F-1 PN: The entry-level CPU for standard and fail-safe applications with medium requirements in terms of processing performance and response speed in discrete production technology. The CPU 1510SP F-1 PN can be used as a PROFINET IO controller or as distributed intelligence (PROFINET I-Device).
CPU 1512SP F-1 PN The CPU for standard and fail-safe applications with medium requirements in terms of processing performance and response speed in discrete production technology. The CPU 1512SP F-1 PN can be used as a PROFINET IO controller or as distributed intelligence (PROFINET I-Device).
CPU 1514SP F-2 PN: The CPU for standard and fail-safe applications with medium/high requirements regarding program scope, networking and processing speed in discrete production technology. For distributed configuration via PROFINET IO. The additional integrated PROFINET interface with separate IP address can be used for network separation, for connecting further PROFINET IO RT devices, or for high-speed communication as an I-Device, for example.
Technology CPUs
CPU 1514SP T-2 PN: For applications with medium/high requirements regarding program scope, networking and processing speed. For distributed configuration via PROFINET IO. The additional integrated PROFINET interface with separate IP address can be used for network separation, for connecting further PROFINET IO RT devices, or for high-speed communication as an I-Device, for example.
CPU 1514SP TF-2 PN: For standard and fail-safe applications with medium/high requirements regarding program scope, networking and processing speed. For distributed configuration via PROFINET IO. The additional integrated PROFINET interface with separate IP address can be used for network separation, for connecting further PROFINET IO RT devices, or for high-speed communication as an I-Device, for example.
ET 200SP Open Controller
CPU 1515SP PC (+HMI): For applications with higher requirements in terms of program scope and processing speed, for distributed configurations via PROFINET IO or PROFIBUS DP. Especially suitable for solutions with high data volumes, C integration, open Windows applications or integrated HMI functions.
Design
ENG_451294.XML
All CPUs have a rugged, compact enclosure.
The front of the controller contains:
LEDs to indicate status and errors
Mode switch
24 V DC connection
The CPUs also include:
a slot for the SIMATIC Memory Card; Note: The SIMATIC Micro Memory Card is essential for operating the ET 200SP CPU. No SIMATIC Memory Card is required for the ET 200SP Open Controller.
Connection for PROFINET IO IRT (3-port switch)
Port 1 and 2 via a BusAdapter
Port 3 permanently integrated in the CPU
Connection for PROFIBUS DP via an optional CM DP communication module (for ET 200SP CPUs and Open Controller)
Connection for PROFINET IO IRT (2-port switch) via BusAdapter (for ET 200SP Open Controller)
Ethernet connection via GB-Ethernet interface (for ET 200SP Open Controller)
Function
ENG_451295.XML
Performance
Fast command processing, depending on the CPU type, language extensions and new data types
High-performance network connection: via PROFINET IO IRT.
Integrated technology
All SIMATIC S7-1500 CPUs support Motion Control functions. STEP 7 provides Motion Control instructions that are standardized in accordance with PLCopen for configuring and connecting a drive to the CPU.
The ET 200SP CPUs supports the following Motion Control technology objects: Speed axes, Positioning axes Synchronized axes (relative synchronism with synchronization, without specification of the synchronous position, setpoint linkage), External encoders, Output cams, Cam track, Probes.
The ET 200SP technology CPUs also offer advanced Motion Control functions: Extended synchronous operation functions, Velocity gearing, Synchronization with specification of the synchronous position, Actual value linkage, Corrections of the leading or following value at the following axis, Camming, Cross-PLC synchronous operation, Cyclic cam, Up to 4 encoder or measuring systems as actual position for position control, Cyclic specification of the motion vector from the application (MotionIn interface), also as overlaid movement, Technology object for controlling kinematics with up to 4 interpolating axes, e.g. Cartesian portal, delta picker, roller picker, articulated arm, cylindrical robot, tripod picker and SCARA, SIMATIC Motion Interpreter - technology object for programming and controlling axes and kinematics
Isochronous mode
Synchronous coupling of distributed signal acquisition, signal transmission, and program execution to the PROFINET cycle with constant bus cycle time
Security Integrated
Password-based know-how protection against unauthorized read-out and modification of program blocks
Copy protection for tying individual blocks to the serial number of the SIMATIC Memory Card: The block can only run if the configured memory card is inserted in the CPU.
4-stage authorization concept: Communication to HMI devices can also be restricted.
Manipulation protection: The controller recognizes changed or unauthorized transmission of the engineering data.
Integrated system diagnostics
System diagnostics information is displayed consistently and in plain text in TIA Portal, HMI devices and web server, even for messages from the drives, and is updated even if the CPU is in STOP mode.
Integrated in the firmware of the CPU, no special configuration is required
Configuration control (option handling) in central setup
Various hardware configurations can be stored in the controller: Modification of the configuration in the user program (startup OB100) Retrofitting of options at end of configuration Use of placeholder modules is possible.
SIMATIC Memory Card (required for operation of the CPU)
Used as plug-in load memory or for updating the firmware.
Also for storing additional documents or csv files (for recipes and archives)
Creation of data blocks and storage/reading of data via SFCs of the user program
Windows, runtime, project data and program are all stored on the CFast card supplied for ET 200SP Open Controllers. The slot for the memory card is used in this case only as an additional drive for Windows.
CFast card for ET 200SP Open Controller (included in delivery package)
Preinstalled S7-1500 Software Controller
Preinstalled operating system and optionally preinstalled WinCC Runtime Advanced software
Data log (archives) and recipes
Storage of csv files for recipes and archives on the SIMATIC Memory Card; easy access to plant-relevant operating data using Office tools and via web server
Easy access to configuration data of the machine by means of a web browser or SD card reader (two-way data exchange from and to the controller)
Programming
Programming with STEP 7 Professional, V13 update 3 and higher (ET 200SP Open Controller: V13 SP1 or higher)
More information
ENG_451296.XML
More information and downloads
Manuals