ASIsafe
|
|
ASIsafe enables the integration of safety-related components in an AS-Interface network, for example:
- EMERGENCY-STOP pushbuttons
- Protective door switches
- Cable-operated switches
- Other AS‑i safety sensors
Your advantage: The simple wiring of AS‑Interface is maintained.
|
|
P_IC01_XX_00652
AS‑i Master and AS‑i Safety module
|
AS‑i Master and AS‑i Safety module for ET 200SP
The CM AS‑i Master ST and F‑CM AS‑i Safety ST modules are plugged into an ET 200SP configuration and connect an AS‑i network, including safety-related inputs and outputs, with the controller.
- Single, double and multiple masters possible
- Per CM AS‑i Master ST module up to 496 DI/496 DQ/124 AI/124 AQ possible
- Per F‑CM AS‑i Safety ST module up to 31 safe input signals (2-channel)/16 safe output channels possible
- Configuring with TIA Portal or STEP 7 (Classic)
- Plant-wide safety programming of the F‑CPU via SIMATIC Distributed Safety/Safety Advanced/F systems
- Integrated diagnostics
- No other programming tools required
Your advantage: Modular connection of fail-safe AS-i networks with system-wide programming in SIMATIC and SINUMERIK controllers.
|
6ES7
|
P_NSW0_XX_00910
K45F
|
AS-Interface safety modules
- Complete portfolio of ASIsafe modules
- For connection of safety switches with contacts (e.g. position switches)
- Degree of protection IP65/IP67 or IP20
- Especially compact dimensions, with widths from 17.5 mm
- Up to four safe inputs per module
- Standard outputs are available on the module in addition
- Up to SIL 3/PL e
Your advantage: Easy integration of safe signals both in the control cabinet and in the field.
|
3RK1
|
G_IC03_XX_16543
SC17.5F
|
P_NSC0_XX_00459
Safety switch
|
SIRIUS 3SF1 mechanical safety switches for AS-Interface
- Plastic with degree of protection IP65 and metal with degree of protection IP66/IP67
- ASIsafe electronics integrated into the enclosure
- Available with separate actuator, with or without tumbler
Your advantage: Conventional wiring of safety functions no longer required.
|
3SF1
|
G_IC03_XX_07214
EMERGENCY-STOP mushroom pushbutton in enclosure
|
SIRIUS ACT EMERGENCY-STOP mushroom pushbuttons for AS‑Interface
- Degree of protection IP66/IP67/IP69 (IP69K)
- Metal or plastic version
- Connection of an EMERGENCY-STOP device according to ISO 13850 to AS-Interface
- Safety-related AS-Interface module is snapped onto the commanding device from behind
- Can be used up to SIL 3/PL e
Your advantage: Easy direct connection of control elements to ASIsafe.
|
3SU14 modules
3SU18 enclosure
|
Masters
|
|
The AS‑Interface master connects SIMATIC controllers to AS-Interface. It automatically organizes the data traffic on the AS‑Interface cable and handles not only signal processing, but also parameter setting, monitoring and diagnostics functions.
|
|
|
Masters for SIMATIC ET 200
|
|
P_IC01_XX_00794
CM AS‑i Master ST for SIMATIC ET 200SP
|
CM AS‑i Master ST for SIMATIC ET 200SP
- Connection of up to 62 AS-Interface slaves per master
- Connection of up to 496 inputs and 496 outputs per AS-Interface network
- Integrated analog value transmission
- Simple configuration by adopting the actual configuration in the AS-Interface network
- Easy operation in the input/output address range of the SIMATIC (or other controller) comparable to standard I/O modules
- Monitoring of the control supply voltage on the AS-Interface shaped cable
- Integrated ground fault monitoring
Your advantage: Easy connection of AS-i networks to distributed I/Os.
|
3RK7
|
P_IC01_XX_00793
F‑CM AS‑i Safety ST for SIMATIC ET 200SP
|
F‑CM AS‑i Safety ST for SIMATIC ET 200SP
- 31 fail-safe AS-i input slaves per F-CM
- 16 fail-safe AS-i outputs per F-CM
- Transmission via PROFIsafe into the F‑CPU for safety-related applications up to SIL 3 (IEC 62061)/PL e (ISO 13849‑1)
- As a result, these sensors become part of the "unlimited programming and data archiving" options of SIMATIC and of Safety Integrated.
Your advantage: Easy connection of fail-safe AS-i networks to the distributed I/Os.
|
3RK7
|
P_NSA0_XX_01395
CM 1243‑2 for SIMATIC S7‑1200
|
Masters for SIMATIC S7
AS‑Interface master connections:
- CM 1243‑2 for SIMATIC S7‑1200
- CP 343‑2P, CP 343‑2 for SIMATIC S7‑300 and ET 200M
Features:
- Connection of up to 62 AS-Interface slaves
- Connection of up to 496 inputs and 496 outputs per master or AS-Interface network
- Integrated analog value transmission
- Simple configuration by adopting the actual configuration in the AS‑Interface network
- Easy operation in the input/output address range of the SIMATIC S7 comparable to standard I/O modules
- Monitoring of the control supply voltage on the AS-Interface shaped cable
Your advantage: Easy connection to SIMATIC controllers.
|
3RK7
6GK7
|
P_IK10_XX_00374
CP 343‑2, CP 343‑2P for SIMATIC S7‑300
|
Gateways
|
P_IK10_XX_00139
DP/AS‑Interface Link 20E
|
- Degree of protection IP20
- PROFIBUS DP slave and AS‑Interface master
- Connection of up to 62 AS-Interface slaves per AS-Interface network
- Connection of up to 496 inputs and 496 outputs per AS-i network
- Integrated analog value transmission
- Configuring and uploading of AS‑Interface configuration in STEP 7 possible
- User-friendly selection of AS-Interface slaves
Your advantage: Compact transition to PROFIBUS A high-performance gateway can be set up between PROFINET and AS‑Interface by combining the CM AS‑i Master ST and F‑CM AS‑i Safety ST modules in an ET 200SP station (for safety-related applications).
|
6GK1
|
Slaves
|
|
Slaves contain the AS‑Interface electronics and connection options for sensors and actuators in the field and in the control cabinet. A total of up to 62 slaves can be connected to one bus. The slaves then exchange their data in cyclic mode with a control module (master).
|
|
|
I/O modules for use in the field, high degree of protection
|
|
P_NSW0_XX_00844
K20 digital module
|
Digital I/O modules, IP67 - K60, K60R, K45 and K20
- Degree of protection IP65/IP67 or IP68/IP69 (IP69K)
- Modules available with up to degree of protection IP68/IP69 (IP69K)
- Connection sockets in M8/M12
- Up to eight inputs and four outputs
- A/B technology available
- Contacting protected against polarity reversal
- DIN-rail mounting and wall mounting possible
- Mounting of the module on the base plate using just one screw
- Diagnostics LEDs
Your advantage: Reduction of mounting and startup times by up to 40%.
|
3RK1, 3RK2
|
P_NSA0_XX_00374
K45 digital module
|
P_NSA0_XX_00232
K60 digital module
|
P_NSA0_XX_00455
K60 analog module
|
Analog I/O modules IP67 - K60
- Degree of protection IP65/IP67
- Detects or transmits analog signals locally
- 2-/4-channel
- Input modules for up to four current, voltage or thermal resistance sensors
- Output modules for current or voltage
Your advantage: Easy integration of analog values.
|
3RK1
|
G_IC03_XX_16555
SlimLine Compact SC17.5
|
G_IC03_XX_16567
SlimLine Compact SC22.5
|
I/O modules for use in the control cabinet
- Degree of protection IP20
- No M12 plugs required for connection
- Especially narrow design for SlimLine Compact modules with widths of 17.5 mm and 22.5 mm
- Analog modules are also available
- Removable, finger-safe terminal blocks that cannot be inadvertently interchanged when using the SlimLine Compact modules
- Flat design of the flat modules for small control boxes and confined conditions
- Connection with screw terminals or spring-loaded terminals
- DIN-rail mounting and wall mounting possible
- Diagnostics LEDs
Your advantage: Modules enable space-saving use in control cabinets and small local control boxes.
|
3RG9, 3RK1, 3RK2
|
P_NSA0_XX_00255
F90 module
|
P_NSA0_XX_00440
Flat module
|
|
Modules with special functions
|
|
P_NSA0_XX_00369
Counter module
|
Counter modules
- Degree of protection IP20
- For evaluation of pulses
- Connection with screw terminals or spring-loaded terminals
Your advantage: Evaluation of pulses which exceed even the clock frequency of AS‑Interface.
|
3RK1
|
P_NSA0_XX_00370
Ground fault detection module
|
Ground fault detection modules
- Degree of protection IP20
- Display using LEDs
- Two signaling outputs
Your advantage: Automatic diagnostics of ground faults on AS‑Interface.
|
3RK1
|
P_NSA0_XX_01387
Overvoltage protection module
|
Overvoltage protection modules
- Degree of protection IP67
- Discharge through ground cable with oil-proof outer sheath
- Protection at transition of lightning protection zones
Your advantage: The AS-Interface overvoltage protection module protects downstream AS-Interface devices or individual sections in AS-Interface networks from conducted overvoltages.
|
3RK1
|
|
Contactors and contactor assemblies
|
|
G_IC03_XX_08771
SIRIUS 3RT203.‑1NB30‑0CC0 contactor
|
SIRIUS 3RT contactors, 3‑pole up to 250 kW
SIRIUS 3RA23 reversing contactor assemblies, up to 55 kW
SIRIUS 3RA24 contactor assemblies for star-delta (wye-delta) starting, up to 90 kW
- Notable reduction of wiring in the control circuit
- Integrated mechanical interlocking
- Prevention of wiring errors in the main circuit
|
3RT20
3RA23
3RA24
|
G_NSA0_XX_92402
SIRIUS 3RA2712 function module
|
SIRIUS 3RA27 function modules
- Connection of 3RT20 power contactors with communication capability, 3RA23 reversing contactor assemblies, and 3RA24 contactor assemblies for star-delta (wye-delta) starting to AS‑Interface
- Reduction of control current wiring through plug-in design and integrated monitoring of circuit breaker/motor starter protector and contactor
- Reduced space requirement in the control cabinet through fewer digital inputs and outputs in the control system
- Easy configuration through operation of feeders instead of individual contactors
- Enhanced operational reliability and quick wiring thanks to spring-loaded terminals
- Small number of versions through use of identical modules for size S00 to S3 contactors
Your advantage: Shortening of mounting and startup times.
|
3RA2712
|
|
Motor starters for use in the control cabinet
|
3RA6
|
P_NSB0_XX_01275
3RA61 compact starter
G_IC03_XX_08296
AS-i enclosure
|
SIRIUS 3RA6 compact starters
3RA61 direct-on-line starters, 3RA62 reversing starters
- Degree of protection IP20
- Very compact load feeders with the integrated functionality of an electronic overload relay
- As direct-on line or reversing starters for motors up to 15 kW/400 V
- Easy expansion into a communication-capable load feeder using AS‑i add-on modules
- On-site safe disconnection also possible using AS‑i add-on modules
- Standardized integration of the loads in higher-level control systems using AS‑i
Your advantage: Compact solution with minimum wiring outlay for actuating direct-on-line and reversing starters in the control cabinet.
|
3RA61, 3RA62
|
P_NSB0_XX_01500
SIRIUS M200D motor starters
|
Motor starters for use in the field, high degree of protection
SIRIUS M200D motor starters for AS‑Interface
- High degree of protection IP65 for cabinet-free design
- As direct‑on-line or reversing starters for motors up to 5.5 kW/400 V
- Mechanical or electronic switching for high switching frequencies
- Optional with manual operation and brake actuation
- Expanded diagnostics and parameterization possible through AS-Interface
- Easy and consistent integration in STEP 7 through AS-Interface
Your advantage: The correct solution for all simple applications in conveyor systems with spatially distributed drives.
|
3RK1
|
P_D011_XX_01395
SINAMICS G115D frequency converter, wall-mounted
|
SINAMICS G115D distributed converters
- Robust, with degree of protection IP65/IP66, and wide operating temperature range from -30 to +55 °C
- Wide power range from 0.37 to 7.5 kW
- Preconfigured with geared motors
- Local commissioning via DIP switch, USB interface and potentiometer or SINAMICS G120 Smart Access
- Integrated safety function:
STO (Safe Torque Off) via fail-safe digital input F‑DI or PROFIsafe and, from firmware V4.7 SP14 in conjunction with SINAMICS Startdrive V18 SP1 or higher, SLS (Safely-Limited Speed) with Safety Extended license
- Integrated applications for conveyor systems, e.g. for roller conveyor, rotary table, transfer carriage
- Expanded diagnostics and parameterization through AS‑Interface
- Flexible connection method for cables, choice of screw connection or plug-in design, compatible with SINAMICS G120D
- Optional maintenance switch (SINAMICS G115D, wall-mounted)
- Optional manual local operation (SINAMICS G115D, wall-mounted)
Your advantage: The simple solution for consistent implementation of distributed plant concepts with requirements for variable-speed drives with Safety functionality.
|
SINAMICS G115D, wall-mounted: 6SL352
|
|
Commanding and signaling devices
|
|
G_IC03_XX_07387
AS‑Interface module
|
SIRIUS ACT pushbuttons and indicator lights for AS‑Interface
- AS‑Interface modules for snap-on mounting on front plate
- AS‑Interface modules for base mounting or mounting in enclosure
- Modular configuration of enclosure based on individual specifications
- Enclosures with standard fittings
- Up to six command points for standard signals or EMERGENCY STOP
- Degree of protection IP66/IP67/IP69 (IP69K)
- Metal or plastic version
- Indicator lights with integrated LED
- Any change of equipment possible even after installation
Your advantage: Complete operating system with simple AS‑Interface integration for your plant.
|
3SU14 modules
3SU18 enclosure
|
P_NSW0_XX_00272
8WD42, 8WD44 signaling column
|
P_NSC0_XX_00134
AS‑Interface adapter element
|
SIRIUS 8WD42 and 8WD44 signaling columns
- Many optical and acoustic elements can be combined
- Up to four signaling elements can be connected using an AS-Interface adapter element
- With integrated LEDs or with BA15d base for LEDs/incandescent lamps
- For fastening to connection elements (screw or spring-loaded terminals)
- 24 V DC, 50 mm (8WD42) diameter and 70 mm diameter (8WD44)
- Connection with bayonet mechanism
Your advantage: Signaling columns for monitoring production sequences and for visual or acoustic warnings in emergency situations, with easy AS‑Interface connection.
|
8WD42, 8WD44
|
Power supply units and data decoupling modules
|
|
AS-Interface power supply units generate a controlled direct voltage of 30 V DC with high stability and low residual ripple in conjunction with data decoupling. They are an integral component of the AS‑Interface network and enable the simultaneous transmission of data and energy on one cable.
In conjunction with data decoupling modules, AS‑Interface can also be operated with standard power supply units.
|
|
P_NSA0_XX_00527
IP20, 3 A
|
AS-Interface power supply units
- With wide performance spectrum from 2.6 to 8 A
- Degree of protection IP20
- Separation of data and energy by means of the integrated data decoupling
- UL/CSA approval means the power supplies can be used worldwide,
2.6 A version with output power restricted to max. 100 W (for Class 2 circuits in accordance with NEC)
- Certified for global use
- Integrated ground fault and overload detection save the need for additional components and make applications reliable
- Diagnostics memory, remote signaling and remote RESET allow fast detection of faults in the system
- Ultra-wide input range permits 1-phase and 2-phase use (8 A version).
Your advantage: Optimum performance for each application.
|
3RX9
|
P_NSA0_XX_00529
IP20, 8 A
|
P_IC02_XX_00227
PSN130S, 30 V DC, 8 A
|
30 V power supply units
Standard 30 V power supply units without data decoupling
- Power spectrum 3 A, 4 A and 8 A
- Overload and short-circuit-proof in every performance class
- Diagnostics: With output voltage > 26.5 V DC
LED and signaling contact for output voltage 30 V O.K.
- Primary-side connection to 120/230 V AC (1-phase) with automatic range selection
Your advantage: Economical alternatives in conjunction with data decoupling modules while making full use of the maximum AS‑Interface cable length.
|
3RX9
|
P_KT01_XX_01128
SITOP PSU100M, 24 V DC, 20 A
|
24 V power supply units
Standard 24 V power supply units (SITOP), without data decoupling
- Power spectrum 2.5 to 40 A
- Overload and short-circuit-proof in every performance class
- Add-on modules for signaling, redundancy, buffering and UPS
- 1-, 2- and 3-phase versions
Your advantage: Economical alternatives in conjunction with data decoupling modules.
|
6EP
|
P_NSW0_XX_01585
S22.5 data decoupling module
|
S22.5 data decoupling modules
- Degree of protection IP20, narrow design 22.5 mm
- Supply of several AS-i networks with a single power supply unit
- Single and double data decoupling
- Operation with 24 V DC or 30 V DC
Your advantage: Cost-effective installation of AS‑i networks in conjunction with standard power supply units.
|
3RK1
|
P_NSA0_XX_01396
DCM 1271 data decoupling module
|
DCM 1271 data decoupling modules for SIMATIC S7‑1200
- Simple data decoupling in IP20 design
- Supply of several AS-i networks with a single power supply unit
- Operation with 24 V DC or 30 V DC
Your advantage: Cost-effective installation of AS‑i networks in conjunction with standard power supply units in the design of a SIMATIC S7‑1200 module.
|
3RK7
|
Transmission media
|
|
AS‑Interface shaped cable for connection of network stations
|
|
G_IC03_XX_19191
Shaped cable
|
AS‑Interface shaped cable
- No polarity reversal thanks to trapezoidal shape
- Cables made of optimized material for different operating conditions
- Special version according to UL Class 2 available
Your advantage: Fast replacement and connection to AS‑Interface by piercing method.
|
3RX9
|
System components and accessories
|
|
Accessories comprise tools for mounting, installation and operating as well as individual components.
|
|
P_IK10_XX_01099
Repeater
|
Repeaters and extension plugs
- Repeaters for extending the AS-Interface cable by 100 m per repeater
- Extension plug for extending the AS-Interface segment to max. 200 m
- Parallel connection of several repeaters possible (star configuration option)
- Maximum size increases (when combined) to more than 600 m
- Easy mounting
- IP67 module enclosure
Your advantage: Lower infrastructure costs, more possibilities of use and greater freedom for plant planning.
|
6GK1 repeater
3RK1 extension plug
|
P_IC01_XX_00191
Compact extension plug
|
P_IC02_XX_00023
Addressing unit for AS‑Interface V 3.0
|
Addressing units
- Reading out and adjusting the slave address 0 to 31 or 1A to 31A, 1B to 31B, with automatic addressing aid and prevention of double addresses
- Reading out the slave profile (IO, ID, ID2) and reading out and setting the ID1 code
- Input/output test when commissioning the slaves, on all digital and analog slaves according to AS-Interface specification V3.0, including safe input slaves and complex CTT2 slaves
- Display of the operational current in case of direct connection of an AS-i slave (measuring range from 0 to 150 mA)
- Storage of complete network configurations (profiles of all slaves) to simplify the addressing
Your advantage: Easiest way to address and test the slaves.
|
3RK1
|
P_NSA0_XX_00588
Analyzer
|
AS-Interface analyzer
- Diagnostic units for completely checking the quality and function of an AS‑Interface installation
- Transmission of collected data through an RS 232 interface to a PC, evaluation by software
- Easy and user-friendly operation
- Automatically generated test logs
- Advanced trigger functions enable exact analysis
- Process data can be monitored online
- In addition to digital I/O data it is possible to view analog values and safety slaves in data mode.
Your advantage: Preventative testing of an AS‑Interface network is possible, recorded logs facilitate remote diagnostics.
|
3RK1
|
P_NSA0_XX_00366
M12 sealing cap
P_NSA0_XX_00331
Cable end terminator
|
Miscellaneous accessories
Individual components such as sealing caps, cable adapters, distributors, M12 plugs and cables, cable end terminator, etc.
|
3RK1, 3RX9, 6ES7
|
Diagnostics
|
S_IC01_XX_00163
Diagnostics for AS‑Interface via HMI panels
|
The following diagnostics block with visualization via HMI or web browser for AS‑Interface can be downloaded free of charge in SiePortal:
Diagnostics blocks
Your advantage: Detailed diagnostics display for fast fault analysis and short downtimes - for easy integration into STEP 7 projects.
|
--
|
Software
|
S_NSA0_XX_00341
AS‑Interface block library for PCS 7
|
AS-Interface block library for SIMATIC PCS 7
- Engineering and runtime software
- Easy connection of AS‑Interface to PCS 7
- Engineering work reduced to positioning and connecting the blocks in the CFC
- No additional configuring steps required for connection to the PCS 7 Maintenance Station, diagnostics for the AS‑i system optimally guaranteed
Your advantage: Easy connection of AS‑Interface to PCS 7, little engineering and configuration.
|
3ZS1635
|