Non-residential buildings
|
Residential buildings
|
Industry
|
 P_I201_XX_04779 |
NEOZED fuse system
|
|
MINIZED switch disconnectors, bases, fuse links from 2 A to 63 A of operational class gG, and accessories. In other words, a complete system.
|
Fuse system: IEC 60269-3; DIN VDE 0636-3;
Safety switching devices:
IEC/EN 60947-3 DIN VDE 0638; EN 60947-3 (VDE 0660-107)
|
✓
|
✓
|
✓
|
|
DIAZED fuse system
|
|
Fuse links from 2 A to 100 A in various operational classes, base versions with conventional screw base connections. A widely used fuse system.
|
IEC 60269-3; DIN VDE 0635; DIN VDE 0636-3; CEE 16
|
✓
|
✓
|
✓
|
Cylindrical fuse systems
|
 P_I201_XX_05882 |
Cylindrical fuse links and cylindrical fuse holders
|
|
Line protection or protection of switching devices.
The fuse holders with touch protection ensure the safe “no-voltage” replacement of fuse links.
Auxiliary switches can be retrofitted.
|
IEC 60269-1, -2, -3; NF C 60-200; NF C 63-210, -211; NBN C 63269-2, CEI 32-4, -12
Fuse holder: File no. E171267
|
✓
|
✓
|
✓
|
 P_I202_XX_01366 |
Fuse holders in size 10 x 38 mm and Class CC
|
|
For the configuration of safety-related motor starter combinations.
|
IEC 60269-1,-2; IEC 60947-4; UL 4248-1 File No. E171267 CSA 250269, 6225-01
Auxiliary switches: UL 508, File No. E334003
|
✓
|
--
|
✓
|
 P_I201_XX_05309 |
Class CC fuse systems
|
|
Compliant with US standards with UL and CSA approval for exporting OEM customers and machine builders.
A modern design with touch protection conforming to BGV A3 for use as "Branch Circuit Protection".
|
Fuse holders: UL 4248-1, E171267 CSA 22.2
Fuse links: UL 248-4, File no. E258218, CSA 231237, 1422-02 and 1422-82
|
✓
|
✓
|
✓
|
 P_I201_XX_04865 |
Busbar systems
|
|
Busbars for NEOZED fuse bases, NEOZED fuse-disconnectors, MINIZED switch disconnectors, DIAZED fuse systems and for the cylindrical fuse system.
Compact cylindrical fuse holder for busbars
|
EN 60439-1 (VDE 0660-500)
UL 4248-1, E337131
|
✓
|
✓
|
✓
|
LV HRC fuse system
|
 P_I201_XX_04190 |
LV HRC fuse links
|
|
Fuse links from 2 A to 1250 A for selective line protection and plant protection in non-residential buildings, in industry and in power supply companies.
|
IEC 60269-1, -2; EN 60269-1; DIN VDE 0636-2 CSA 16325 - 1422-02
|
✓
|
✓
|
✓
|
 P_I201_XX_04784 |
LV HRC signal indicators
|
|
Signal indicators for blown fuses in all LV HRC fuse links with combination or front indicators with live grip lugs.
And the extensive accessories required for the LV HRC fuses.
|
--
|
✓
|
✓
|
✓
|
 P_I201_XX_04153 |
LV HRC fuse bases and accessories
|
|
Bases for screw or snap-on mounting onto DIN rail in 1-pole or 3-pole version.
|
IEC 60269-1, -2; EN 60269-1; DIN VDE 0636-2
UL 4248-1 File no. E141267-IZLT2 (only behind the branch circuit protection)
CSA C22.2 No. 4248.1-07
|
✓
|
✓
|
✓
|
SITOR semiconductor fuses
|
 P_NSE0_XX_00559 |
LV HRC design
|
|
Fuse links of the LV HRC design in numerous versions for many applications ranging from 500 V to 1500 V and from 150 A to 1600 A.
Fuses with slotted knife blade contacts, bolt-on lugs or female threads, special designs.
|
UL 4248-13, File no. E167357-JFHR2
|
--
|
--
|
✓
|
 P_NSE0_XX_00541 |
Design: cylinder fuses
|
|
Fuse links, fuse holders – can be used as fuse switch disconnectors and fuse bases up to 600/690 V AC and 400/700 V DC from 1 A to 100 A in sizes 10 × 38 mm, 14 × 51 mm and 22 × 58 mm.
|
Fuse links: UL 4248-13, File no. E167357-JFHR2 CSA 248170, 6225-01
|
--
|
--
|
✓
|
  P_I201_XX_00279P_I201_XX_04121 |
NEOZED, DIAZED design
|
|
NEOZED fuse links for 400 V AC and 250 V DC and DIAZED for 500 V AC and 500 V DC.
|
--
|
--
|
--
|
✓
|
Photovoltaic fuses
|
 P_I202_XX_00405 |
PV cylindrical fuses
|
|
Fuses with a rated voltage of 1000 V DC and operating class gPV for protecting photovoltaic modules, their connecting cables and other components.
|
IEC 60269-6
|
✓
|
✓
|
✓
|
 P_I202_XX_01759 |
PV summation fuses
|
|
Fuses with a rated voltage of 1000 V and 1500 V DC, a rated current from 63 A to 630 A and operating class gPV for protecting connecting cables and other components.
|
IEC60269-6
|
✓
|
✓
|
✓
|