ENG_669474.XML
P_IK10_XX_00283
K60
P_IK10_XX_00281
K45
P_NSA0_XX_00608
K20
Three coordinated series of AS‑Interface compact modules with digital and analog compact modules and a high degree of protection are available for use in the field:
- Digital modules with a high degree of protection
- K60 series
- K45 series
- K20 series
- Analog modules with a high degree of protection
All compact modules are characterized by particularly simple handling. The K60 and K45 modules are mounted with a mounting plate. The mounting plate is used to mount the AS‑Interface flat cables and enables mounting on a wall or DIN rail.
The particularly narrow K20 modules are directly mounted without a mounting plate and connected to the AS‑Interface using a round cable.
Connection types
For flexible connection of different sensors and actuators, the following pin assignments are available on the I/O modules with M12 sockets:
Standard assignment
With the standard assignment, one sensor/actuator is connected per M12 socket. In this case the signal for the outputs is acquired at pin 4 while the signal for the inputs is acquired at pin 4 and pin 2. As the result, sensors can be connected directly to pin 2 and pin 4.
Y-assignment
With the Y-assignment, two sensors or two actuators can be connected to one M12 socket. In this case, both pin 4 and pin 2 are provided for one sensor signal and one actuator signal on each M12 socket.
In this case, the second socket is not required and is closed with a sealing cap.
Y‑II assignment
The Y-II assignment offers the following options:
- Individual connection of a sensor/actuator to one M12 socket
- Connection of two sensors/actuators to one M12 socket as follows:
- The signal of the first sensor/actuator is connected to pin 4 of the first socket.
- The signal of the second sensor/actuator is connected to pin 2 of the first socket and to pin 4 of the second socket.
Overview of digital compact modules
The following table provides an overview of the important features of the digital compact modules.
Version
|
K60
|
K45
|
K20
|
8 inputs/2 outputs
|
✓
|
--
|
--
|
8 inputs
|
✓
|
✓
|
--
|
4 inputs/4 outputs
|
✓
|
✓
|
✓
|
4 inputs/3 outputs
|
✓
|
--
|
--
|
4 inputs/2 outputs
|
✓
|
--
|
--
|
4 inputs
|
✓
|
✓
|
✓
|
2 inputs/2 outputs
|
--
|
✓
|
✓
|
4 outputs
|
✓
|
✓
|
✓
|
3 outputs
|
--
|
✓
|
--
|
AS‑Interface connection
|
Flat cable/round cable
|
Flat cable
|
Round cable
|
I/O connection method
|
M12
|
M12/M8
|
M12/M8
|
Pin assignment
|
Standard/Y-II/Y
|
Standard/Y
|
Standard/Y
|
Degree of protection
|
IP65/IP67/IP68/IP69 (IP69K)
|
IP65/IP67
|
IP65/IP67
|
Addressing type A/B address
|
✓
|
✓
|
✓
|
✓ Available
-- Not available
For safety modules for AS‑Interface, see here.