General information
|
|
|
Product type designation
|
CPU 1518-4 PN/DP
|
CPU 1518-4 PN/DP MFP
|
based on
|
6ES7518-4AP00-0AB0
|
6ES7518-4AX00-1AC0
|
Product function
|
|
|
|
Yes
|
Yes; With minimum OB 6x cycle of 125 µs
|
Engineering with
|
|
|
|
see entry ID: 109746275
|
see entry ID: 109746275
|
Configuration control
|
|
|
via dataset
|
|
Yes
|
Display
|
|
|
Screen diagonal [cm]
|
6.1 cm
|
6.1 cm
|
Control elements
|
|
|
Number of keys
|
6
|
6
|
Mode selector switch
|
1
|
1
|
Supply voltage
|
|
|
Rated value (DC)
|
24 V
|
24 V
|
permissible range, lower limit (DC)
|
19.2 V
|
19.2 V
|
permissible range, upper limit (DC)
|
28.8 V
|
28.8 V
|
Reverse polarity protection
|
Yes
|
Yes
|
Mains buffering
|
|
|
|
|
5 ms
|
|
|
1/s
|
Input current
|
|
|
Current consumption (rated value)
|
1.55 A
|
1.7 A
|
Current consumption, max.
|
|
2 A
|
Inrush current, max.
|
2.4 A; Rated value
|
2.7 A; Rated value
|
I²t
|
0.45 A²·s
|
0.02 A²·s
|
Power
|
|
|
Infeed power to the backplane bus
|
12 W
|
12 W
|
Power consumption from the backplane bus (balanced)
|
30 W
|
35 W
|
Power loss
|
|
|
Power loss, typ.
|
24 W
|
29 W
|
Memory
|
|
|
Number of slots for SIMATIC memory card
|
|
1
|
SIMATIC memory card required
|
Yes
|
Yes
|
Work memory
|
|
|
|
4 Mbyte
|
4 Mbyte
|
|
20 Mbyte
|
20 Mbyte
|
|
|
50 Mbyte; Note: The "CPU function library of the CPU" are C/C++ blocks for the user program that were created using the SIMATIC ODK 1500S or Target 1500S.
|
Working memory for additional functions
|
|
|
|
|
500 Mbyte
|
Load memory
|
|
|
|
32 Gbyte
|
32 Gbyte; the memory card must have at least 2 GB of space on it
|
Backup
|
|
|
|
Yes
|
Yes
|
CPU processing times
|
|
|
for bit operations, typ.
|
1 ns
|
1 ns
|
for word operations, typ.
|
2 ns
|
2 ns
|
for fixed point arithmetic, typ.
|
2 ns
|
2 ns
|
for floating point arithmetic, typ.
|
6 ns
|
6 ns
|
CPU-blocks
|
|
|
Number of blocks (total)
|
10 000
|
|
Number of elements (total)
|
|
10 000; Blocks (OB, FB, FC, DB) and UDTs
|
DB
|
|
|
|
|
1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
|
|
10 000; Number range: 1 to 65535
|
|
|
10 Mbyte
|
16 Mbyte; For non-optimized block accesses, the max. size of the DB is 64 KB
|
FB
|
|
|
|
|
0 ... 65 535
|
|
9 998; Number range: 1 to 65535
|
|
|
512 kbyte
|
1 Mbyte
|
FC
|
|
|
|
|
0 ... 65 535
|
|
9 999; Number range: 1 to 65535
|
|
|
512 kbyte
|
1 Mbyte
|
OB
|
|
|
|
512 kbyte
|
1 Mbyte
|
|
100
|
100
|
|
20
|
20
|
|
20
|
20
|
|
20
|
20; with minimum OB 3x cycle of 100 µs
|
|
50
|
50
|
|
3
|
3
|
|
2
|
2
|
|
2
|
2
|
|
100
|
100
|
|
4
|
4
|
|
2
|
2
|
|
1
|
1
|
Nesting depth
|
|
|
|
24
|
24
|
Counters, timers and their retentivity
|
|
|
S7 counter
|
|
|
|
2 048
|
2 048
|
Retentivity
|
|
|
|
Yes
|
Yes
|
IEC counter
|
|
|
|
Any (only limited by the main memory)
|
Any (only limited by the main memory)
|
Retentivity
|
|
|
|
Yes
|
Yes
|
S7 times
|
|
|
|
2 048
|
2 048
|
Retentivity
|
|
|
|
Yes
|
Yes
|
IEC timer
|
|
|
|
Any (only limited by the main memory)
|
Any (only limited by the main memory)
|
Retentivity
|
|
|
|
Yes
|
Yes
|
Data areas and their retentivity
|
|
|
Retentive data area (incl. timers, counters, flags), max.
|
768 kbyte; Available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 700 KB
|
768 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 700 KB
|
Extended retentive data area (incl. timers, counters, flags), max.
|
|
20 Mbyte; When using PS 6 0W 24/48/60 V DC HF
|
Flag
|
|
|
|
16 kbyte
|
16 kbyte
|
|
8; 8 clock memory bit, grouped into one clock memory byte
|
8; 8 clock memory bit, grouped into one clock memory byte
|
Data blocks
|
|
|
|
Yes
|
Yes
|
|
No
|
No
|
Local data
|
|
|
|
64 kbyte; max. 16 KB per block
|
64 kbyte; max. 16 KB per block
|
Address area
|
|
|
Number of IO modules
|
8 192
|
16 384; max. number of modules / submodules
|
I/O address area
|
|
|
|
32 kbyte; All inputs are in the process image
|
32 kbyte; All inputs are in the process image
|
|
32 kbyte; All outputs are in the process image
|
32 kbyte; All outputs are in the process image
|
per integrated IO subsystem
|
|
|
|
16 kbyte; 16 KB via the integrated PROFINET IO interface, 8 KB via the integrated DP interface
|
16 kbyte; 16 KB via the integrated PROFINET IO interface X1, 8 KB via the integrated PROFINET IO interface X2 and via the integrated PROFIBUS DP interface
|
|
16 kbyte; 16 KB via the integrated PROFINET IO interface, 8 KB via the integrated DP interface
|
16 kbyte; 16 KB via the integrated PROFINET IO interface X1, 8 KB via the integrated PROFINET IO interface X2 and via the integrated PROFIBUS DP interface
|
per CM/CP
|
|
|
|
8 kbyte
|
8 kbyte
|
|
8 kbyte
|
8 kbyte
|
Subprocess images
|
|
|
|
32
|
32
|
Hardware configuration
|
|
|
Number of distributed IO systems
|
10
|
64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
|
Number of DP masters
|
|
|
|
1
|
1
|
|
8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
|
8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
|
Number of IO Controllers
|
|
|
|
1
|
2
|
|
8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
|
8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
|
Rack
|
|
|
|
32; CPU + 31 modules
|
32; CPU + 31 modules
|
|
1
|
1
|
PtP CM
|
|
|
|
the number of connectable PtP CMs is only limited by the number of available slots
|
the number of connectable PtP CMs is only limited by the number of available slots
|
Time of day
|
|
|
Clock
|
|
|
|
Hardware clock
|
Hardware clock
|
|
6 wk; At 40 °C ambient temperature, typically
|
6 wk; At 40 °C ambient temperature, typically
|
|
10 s; Typ.: 2 s
|
10 s; Typ.: 2 s
|
Operating hours counter
|
|
|
|
8
|
16
|
Clock synchronization
|
|
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
Interfaces
|
|
|
Number of PROFINET interfaces
|
3
|
3
|
Number of PROFIBUS interfaces
|
1
|
1
|
1. Interface
|
|
|
Interface types
|
|
|
|
Yes
|
Yes; X1
|
|
2
|
2
|
|
Yes
|
Yes
|
Protocols
|
|
|
|
|
Yes; IPv4
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes; MRP Automanager according to IEC 62439-2 Edition 2.0
|
PROFINET IO Controller
|
|
|
Services
|
|
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes; Max. 32 PROFINET devices
|
Yes; Max. 32 PROFINET devices
|
|
512; In total, up to 1 000 distributed I/O devices can be connected via PROFIBUS or PROFINET
|
512; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
|
|
64
|
64
|
|
256
|
512
|
|
256
|
512
|
|
8
|
8; in total across all interfaces
|
|
8
|
8
|
|
The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
|
The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
|
Update time for IRT
|
|
|
|
|
125 µs
|
|
|
187.5 µs
|
|
250 µs to 4 ms
|
250 µs to 4 ms
|
|
500 µs to 8 ms
|
500 µs to 8 ms
|
|
1 ms to 16 ms
|
1 ms to 16 ms
|
|
2 ms to 32 ms
|
2 ms to 32 ms
|
|
4 ms to 64 ms
|
4 ms to 64 ms
|
|
Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)
|
Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)
|
Update time for RT
|
|
|
|
250 µs to 128 ms
|
250 µs to 128 ms
|
|
500 µs to 256 ms
|
500 µs to 256 ms
|
|
1 ms to 512 ms
|
1 ms to 512 ms
|
|
2 ms to 512 ms
|
2 ms to 512 ms
|
|
4 ms to 512 ms
|
4 ms to 512 ms
|
PROFINET IO Device
|
|
|
Services
|
|
|
|
Yes
|
Yes
|
|
No
|
No
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
4
|
4
|
|
|
Yes; per user program
|
2. Interface
|
|
|
Interface types
|
|
|
|
Yes
|
Yes; X2
|
|
1
|
1
|
|
No
|
No
|
Protocols
|
|
|
|
|
Yes; IPv4
|
|
No
|
Yes
|
|
No
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
|
No
|
PROFINET IO Controller
|
|
|
Services
|
|
|
|
|
Yes
|
|
|
No
|
|
|
No
|
|
|
Yes
|
|
|
No
|
|
|
128; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
|
|
|
128
|
|
|
128
|
|
|
8; in total across all interfaces
|
|
|
The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
|
Update time for RT
|
|
|
|
|
1 ms to 512 ms
|
PROFINET IO Device
|
|
|
Services
|
|
|
|
|
Yes
|
|
|
No
|
|
|
No
|
|
|
Yes
|
|
|
No
|
|
|
Yes
|
|
|
4
|
|
|
Yes; per user program
|
3. Interface
|
|
|
Interface types
|
|
|
|
Yes
|
Yes; X3
|
|
1
|
1; C/C++ Runtime can also be reached via this port
|
|
No
|
No
|
Protocols
|
|
|
|
|
Yes; IPv4
|
|
No
|
No
|
|
No
|
No
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
PROFIBUS DP master
|
|
|
|
48; for the integrated PROFIBUS DP interface
|
48; for the integrated PROFIBUS DP interface
|
|
125; In total, up to 1 000 distributed I/O devices can be connected via PROFIBUS or PROFINET
|
125; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
|
Services
|
|
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
4. Interface
|
|
|
Interface types
|
|
|
|
Yes
|
Yes; X4
|
|
1
|
1
|
Protocols
|
|
|
|
Yes
|
Yes
|
|
No
|
No
|
|
Yes
|
Yes
|
PROFIBUS DP master
|
|
|
|
48; for the integrated PROFIBUS DP interface
|
|
Services
|
|
|
|
Yes
|
|
|
Yes
|
|
Interface types
|
|
|
RJ 45 (Ethernet)
|
|
|
|
Yes
|
Yes
|
|
|
Yes; Only possible at the X3 interface of the CPU 1518
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
RS 485
|
|
|
|
12 Mbit/s
|
12 Mbit/s
|
Protocols
|
|
|
PROFIsafe
|
No
|
No
|
Number of connections
|
|
|
|
384; via integrated interfaces of the CPU and connected CPs / CMs
|
384; via integrated interfaces of the CPU and connected CPs / CMs
|
|
10
|
10
|
|
192
|
192
|
|
64; in total, only 16 S7-Routing connections are supported via PROFIBUS
|
64; in total, only 16 S7-Routing connections are supported via PROFIBUS
|
Redundancy mode
|
|
|
Media redundancy
|
|
|
|
Yes; as MRP redundancy manager and/or MRP client; max. number of devices in the ring: 50
|
Yes; as MRP redundancy manager and/or MRP client; max. number of devices in the ring: 50
|
|
|
Yes; Requirement: IRT
|
|
200 ms
|
200 ms; For MRP, bumpless for MRPD
|
|
50
|
50
|
SIMATIC communication
|
|
|
|
Yes
|
Yes
|
|
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
See online help (S7 communication, user data size)
|
See online help (S7 communication, user data size)
|
Open IE communication
|
|
|
|
Yes
|
Yes
|
|
64 kbyte
|
64 kbyte
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
64 kbyte
|
64 kbyte
|
|
Yes
|
Yes
|
|
1 472 byte
|
2 kbyte; 1 472 bytes for UDP broadcast
|
|
|
Yes; Max. 5 multicast circuits
|
|
No
|
No
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
Web server
|
|
|
|
Yes; Standard and user-defined pages
|
Yes; Standard and user pages
|
|
Yes; Standard and user-defined pages
|
Yes; Standard and user pages
|
OPC UA
|
|
|
|
|
Yes
|
|
|
Yes; Data access (read, write, subscribe), method call, custom address space
|
|
|
Yes
|
|
|
Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
|
|
|
"anonymous" or by user name & password
|
|
|
64
|
|
|
200 000
|
|
|
50 000
|
|
|
20
|
|
|
10 ms
|
|
|
10 ms
|
|
|
100
|
|
|
20
|
|
|
50 000
|
|
|
10
|
|
|
30 000
|
Further protocols
|
|
|
|
Yes; MODBUS TCP
|
Yes; MODBUS TCP
|
Isochronous mode
|
|
|
Equidistance
|
Yes
|
Yes
|
S7 message functions
|
|
|
Number of login stations for message functions, max.
|
32
|
32
|
Program alarms
|
Yes
|
Yes
|
Number of configurable program messages, max.
|
10 000
|
10 000
|
Number of simultaneously active program alarms
|
1 000
|
|
|
|
1 000
|
|
|
200
|
|
|
160
|
Test commissioning functions
|
|
|
Joint commission (Team Engineering)
|
|
Yes; Parallel online access possible for up to 10 engineering systems
|
Status block
|
Yes; Up to 16 simultaneously
|
Yes; Up to 16 simultaneously (in total across all ES clients)
|
Single step
|
No
|
No
|
Number of breakpoints
|
|
20
|
Status/control
|
|
|
|
Yes
|
Yes
|
|
Inputs, outputs, memory bits, DB, times, counters
|
Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
|
|
|
|
|
200; per job
|
200; per job
|
|
200; per job
|
200; per job
|
Forcing
|
|
|
|
Inputs, outputs
|
Peripheral inputs/outputs
|
|
200
|
200
|
Diagnostic buffer
|
|
|
|
Yes
|
Yes
|
|
3 200
|
3 200
|
|
1 000
|
1 000
|
Traces
|
|
|
|
8
|
8; Up to 512 KB of data per trace are possible
|
Interrupts/diagnostics/status information
|
|
|
Diagnostics indication LED
|
|
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
Supported technology objects
|
|
|
Motion Control
|
Yes
|
Yes; Note: The number of axes affects the cycle time of the PLC program; selection guide via the TIA Selection Tool or SIZER
|
|
|
10 240
|
|
|
|
|
|
40
|
|
|
80
|
|
|
160
|
|
|
80
|
|
|
20
|
|
|
160
|
|
|
40
|
|
|
|
|
128; Up to 128 axes in total (speed-controlled, positioning axis, external encoders) are supported
|
|
|
|
|
|
128; Up to 128 axes in total (speed-controlled, positioning axis, external encoders) are supported
|
|
|
|
128
|
|
|
128
|
|
|
|
|
128; Up to 128 axes in total (speed-controlled, positioning axis, external encoders) are supported
|
|
Controller
|
|
|
|
Yes; Universal PID controller with integrated optimization
|
Yes; Universal PID controller with integrated optimization
|
|
Yes; PID controller with integrated optimization for valves
|
Yes; PID controller with integrated optimization for valves
|
|
|
Yes; PID controller with integrated optimization for temperature
|
Counting and measuring
|
|
|
|
Yes
|
Yes
|
Standards, approvals, certificates
|
|
|
Ecological footprint
|
|
|
|
Yes
|
|
Global warming potential
|
|
|
|
570 kg
|
|
|
96.9 kg
|
|
|
483 kg
|
|
|
-9.97 kg
|
|
Ambient conditions
|
|
|
Ambient temperature during operation
|
|
|
|
0 °C; = Tmin (incl. condensation/frost)
|
0 °C; = Tmin (incl. condensation/frost)
|
|
60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off
|
60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off
|
|
0 °C; = Tmin
|
0 °C; = Tmin
|
|
40 °C; Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off
|
40 °C; Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off
|
Ambient temperature during storage/transportation
|
|
|
|
-40 °C
|
-40 °C
|
|
70 °C
|
70 °C
|
Altitude during operation relating to sea level
|
|
|
|
5 000 m
|
5 000 m
|
|
Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
|
Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
|
Relative humidity
|
|
|
|
100 %; RH incl. condensation/frost (no commissioning under condensation conditions)
|
100 %; incl. condensation / frost permitted (no commissioning under condensation conditions)
|
Resistance
|
|
|
Coolants and lubricants
|
|
|
|
Yes; Incl. diesel and oil droplets in the air
|
Yes; Incl. diesel and oil droplets in the air
|
Use in stationary industrial systems
|
|
|
|
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
|
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
|
|
Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
|
Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
|
|
Yes; Class 3S4 incl. sand, dust, *
|
Yes; Class 3S4 incl. sand, dust, *
|
Use on ships/at sea
|
|
|
|
Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request
|
Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request
|
|
Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
|
Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
|
|
Yes; Class 6S3 incl. sand, dust; *
|
Yes; Class 6S3 incl. sand, dust; *
|
Usage in industrial process technology
|
|
|
|
Yes; Class 3 (excluding trichlorethylene)
|
Yes; Class 3 (excluding trichlorethylene)
|
|
Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
|
Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
|
Remark
|
|
|
|
* The supplied plug covers must remain in place over the unused interfaces during operation!
|
* The supplied plug covers must remain in place over the unused interfaces during operation!
|
Conformal coating
|
|
|
|
Yes; Class 2 for high reliability
|
Yes; Class 2 for high reliability
|
|
Yes; Type 1 protection
|
Yes; Type 1 protection
|
|
Yes; Discoloration of coating possible during service life
|
Yes; Discoloration of coating possible during service life
|
|
Yes; Conformal coating, Class A
|
Yes; Conformal coating, Class A
|
configuration / header
|
|
|
configuration / programming / header
|
|
|
Programming language
|
|
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
Know-how protection
|
|
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
Access protection
|
|
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
programming / cycle time monitoring / header
|
|
|
|
adjustable minimum cycle time
|
adjustable minimum cycle time
|
|
adjustable maximum cycle time
|
adjustable maximum cycle time
|
Open Development interfaces
|
|
|
|
|
9.8 Mbyte
|
Dimensions
|
|
|
Width
|
175 mm
|
175 mm
|
Height
|
147 mm
|
147 mm
|
Depth
|
129 mm
|
129 mm
|
Weights
|
|
|
Weight, approx.
|
1 988 g
|
1 988 g
|