SIMATIC S7-1500F integrated *)
|
|
|
|
✓
|
✓
|
✓
|
✓
|
✓
|
PLC user memory:
Program memory in MB / Data memory in MB
|
|
|
|
✓
1.5 / 5
|
✓
1.5 / 5
|
✓
1.5 / 5
|
✓
1.5 / 5
|
✓
|
|
|
6FC5800‑0BD10‑0YB0
|
D11...D13
|
O
3 / 10
|
O
3 / 10
|
O
6 / 20
|
O
6 / 20
|
O
|
PROFINET IO controller
|
|
|
|
✓
|
✓
|
✓
|
✓
|
✓
|
PROFINET IO device
|
|
|
|
✓
|
✓
|
✓
|
✓
|
✓
|
Fieldbus communication via PROFINET IO RT/IRT (X150):
|
|
|
|
✓
|
✓
|
✓
|
✓
|
✓
|
Number of interfaces / Number of ports (RJ45)
|
|
|
|
1 / 2
|
1 / 2
|
1 / 2
|
1 / 2
|
✓
|
Distributed I/O via PROFINET (RT/IRT):
|
|
|
|
|
|
|
|
|
- Via integrated interface,
data transfer rate X150, max.
|
|
|
|
100 Mbps
|
100 Mbps
|
100 Mbps
|
100 Mbps
|
✓
|
- Minimum update time for IRT
(min. update time is determined by the time slice set for PROFINET IO communication, by the number of IO devices used, and by the amount of configured user data)
|
|
|
|
1 ms
|
1 ms
|
1 ms
|
1 ms
|
✓
|
- Minimum update time for RT
(min. update time is determined by the time slice set for PROFINET IO communication, by the number of IO devices used, and by the amount of configured user data)
|
|
|
|
1 ms
|
1 ms
|
1 ms
|
1 ms
|
✓
|
Distributed PROFINET IO devices, maximum number
|
|
See SiePortal
|
|
255
|
255
|
255
|
255
|
✓
|
- including IO devices with IRT, max.
|
|
|
|
64
|
64
|
64
|
64
|
✓
|
Plant communication via PROFINET IO RT (X160):
|
|
|
|
✓
|
✓
|
✓
|
✓
|
✓
|
Number of interfaces / Number of ports (RJ45)
|
|
|
|
1 / 1
|
1 / 1
|
1 / 1
|
1 / 1
|
✓
|
Distributed I/O via PROFINET (RT):
|
|
|
|
|
|
|
|
|
- Via integrated interface,
data transfer rate X160, max.
|
|
|
|
100 Mbps
|
100 Mbps
|
100 Mbps
|
100 Mbps
|
✓
|
- Update time for RT (for a send clock of 1 ms)
(min. update time is determined by the time slice set for PROFINET IO communication, by the number of IO Devices used, and by the amount of configured user data)
|
|
|
|
1 ms … 512 ms
|
1 ms… 512 ms
|
1 ms … 512 ms
|
1 ms… 512 ms
|
✓
|
Distributed PROFINET IO devices for RT, max. number
|
|
See SiePortal
|
|
128
|
128
|
128
|
128
|
✓
|
Fieldbus communication via PROFIBUS DP (X126):
|
|
|
|
|
|
|
|
|
Number of interfaces:
|
|
|
|
–
|
1
|
1
|
1
|
✓
|
- Data transfer rate X126, max.
|
|
|
|
–
|
12 Mbps
|
12 Mbps
|
12 Mbps
|
✓
|
Distributed PROFIBUS DP Devices, max. number
|
|
|
|
–
|
125
|
125
|
125
|
✓
|
I/O address range
Inputs – all inputs are in the process image (16 KB via integrated PROFINET IO interface X150, 8 KB via integrated PROFINET IO interface X160 and 8 KB via integrated PROFIBUS DP interface X126) 1)
|
|
|
|
32 KB
|
32 KB
|
32 KB
|
32 KB
|
✓
|
I/O address range
Outputs – all outputs are in the process image (16 KB via integrated PROFINET IO interface X150, 8 KB via integrated PROFINET IO interface X160 and 8 KB via integrated PROFIBUS DP interface X126)1)
|
|
|
|
32 KB
|
32 KB
|
32 KB
|
32 KB
|
✓
|
Bit memory
|
|
|
|
16 KB
|
16 KB
|
16 KB
|
16 KB
|
✓
|
S7 timers
|
|
|
|
2048
|
2048
|
2048
|
2048
|
✓
|
IEC timers
|
|
|
|
Any
|
Any
|
Any
|
Any
|
✓
|
S7 counters
|
|
|
|
2048
|
2048
|
2048
|
2048
|
✓
|
IEC counters
|
|
|
|
Any
|
Any
|
Any
|
Any
|
✓
|
Retentive data area
|
|
|
|
768 KB
|
768 KB
|
768 KB
|
768 KB
|
✓
|
Usable retentive memory for bit memories, timers, counters, DBs and technological data (axes)
|
|
|
|
700 bytes
|
700 bytes
|
700 bytes
|
700 bytes
|
✓
|
PLC blocks
Total number of elements (blocks OB, FB, FC, DB) and UDTs
|
|
|
|
12000
|
12000
|
12000
|
12000
|
✓
|
FB:
|
|
|
|
|
|
|
|
|
|
|
|
|
1 MB
|
1 MB
|
1 MB
|
1 MB
|
✓
|
- Largest number
(usable nos. 30 … 999, 1024 … 24999)
|
|
|
|
65535
|
65535
|
65535
|
65535
|
✓
|
FC:
|
|
|
|
|
|
|
|
|
|
|
|
|
1 MB
|
1 MB
|
1 MB
|
1 MB
|
✓
|
- Largest number (usable nos. 30 … 999, 1024 … 24999)
|
|
|
|
65535
|
65535
|
65535
|
65535
|
✓
|
DB:
|
|
|
|
|
|
|
|
|
- max. size
(optimized/non-optimized block access)
|
|
|
|
16 MB / 64 KB
|
16 MB / 64 KB
|
16 MB / 64 KB
|
16 MB / 64 KB
|
✓
|
- Largest number
(usable nos. 62 … 70, 1100 … 24999)
|
|
|
|
59999
|
59999
|
59999
|
59999
|
✓
|
Know-how protection:
|
|
|
|
|
|
|
|
|
|
|
|
|
✓
|
✓
|
✓
|
✓
|
✓
|
|
|
|
|
✓
|
✓
|
✓
|
✓
|
✓
|
|
|
|
|
✓
|
✓
|
✓
|
✓
|
✓
|
|
|
|
|
✓
|
✓
|
✓
|
✓
|
✓
|
- "Write protection" protection level
|
|
|
|
✓
|
✓
|
✓
|
✓
|
✓
|
- "Read/write protection" protection level
|
|
|
|
✓
|
✓
|
✓
|
✓
|
✓
|
- "Complete protection" protection level
|
|
|
|
✓
|
✓
|
✓
|
✓
|
✓
|
SINUMERIK PP 72/48D PN I/O module
|
|
6FC5311-0AA00-0AA0
|
|
O
|
O
|
O
|
O
|
O
|
SINUMERIK PP 72/48D 2/2A PN I/O module
|
|
6FC5311-0AA00-1AA0
|
|
O
|
O
|
O
|
O
|
O
|
- Terminal strip converter for SINUMERIK PP 72/48D I/O module from 50-pin IDC connector to screw-type terminals for 1-to-1 connection
|
|
6EP5406-5AA0
|
|
O
|
O
|
O
|
O
|
O
|
- Cable set for SINUMERIK PP 72/48D PN I/O module for self-assembly, comprising:
- 6 m ribbon cable, 50-pin
- 8 insulation displacement connectors, 50-pin
- Strain relief clamp
|
|
6EP5306-5BG00
|
|
O
|
O
|
O
|
O
|
O
|
Standard motion control functionality:
Extended number of motion control resources, maximum Requirement: from CNC SW 6.20
|
|
|
|
✓
640
|
✓
640
|
✓
720
|
✓
1520
|
✓
|
Company network interface (X130):
|
|
|
|
✓
|
✓
|
✓
|
✓
|
✓
|
Number of interfaces / Number of ports (RJ45)
|
|
|
|
1 / 1
|
1 / 1
|
1 / 1
|
1 / 1
|
✓
|
- Data transfer rate X130, max.
|
|
|
|
1 Gbps
|
1 Gbps
|
1 Gbps
|
1 Gbps
|
✓
|
System network interface (X120):
|
|
|
|
✓
|
✓
|
✓
|
✓
|
✓
|
Number of interfaces / Number of ports (RJ45)
|
|
|
|
1 / 1
|
1 / 1
|
1 / 1
|
1 / 1
|
✓
|
- Data transfer rate X120, max.
|
|
|
|
1 Gbps
|
1 Gbps
|
1 Gbps
|
1 Gbps
|
✓
|
Service network interface (X127):
|
|
|
|
✓
|
✓
|
✓
|
✓
|
✓
|
Number of interfaces / Number of ports (RJ45)
|
|
|
|
1 / 1
|
1 / 1
|
1 / 1
|
1 / 1
|
✓
|
- Data transfer rate X127, max.
|
|
|
|
1 Gbps
|
1 Gbps
|
1 Gbps
|
1 Gbps
|
✓
|